Home > Hong Kong > Office acoustics and soundproofing

Modern office interior with acoustic treatment

For projects in Hong Kong

Office acoustics and soundproofing in Hong Kong

Three separate problems get called one problem: speech carrying across an open floor, meeting rooms that leak, and hard rooms that ring. Each has a different answer and mixing them up is how budgets get wasted. Central plant, split units and VRF packed into light wells and podium decks close to every flat.

Open plan
Distraction distance, not reverberation time. Ceiling absorption plus screens at the desk.
Meeting rooms
Privacy between rooms. That is partition and door work, not panels.
Cabins and calls
Short RT so a call sounds clean. A small amount of well placed absorber.
Quote
From a plan and a section, within 48 hours

01 / What it is

The material, and what it actually does on a Hong Kong job

Three separate problems get called one problem: speech carrying across an open floor, meeting rooms that leak, and hard rooms that ring. Each has a different answer and mixing them up is how budgets get wasted.

Central plant, split units and VRF packed into light wells and podium decks close to every flat.

Work reaching us from Hong Kong is mostly apartments, offices, hotels and dining, clinics, schools, studios.

  • Depth is the expensive part Every millimetre a wall grows into the room is paid for at Hong Kong rates. A dense thin membrane usually beats a thicker framed build-up here on total cost.
  • Concrete towers, live rooms The structure blocks a great deal already. The problem is hard interiors and impact through slabs rather than airborne transfer.
  • Plant on every roof and podium Cooling plant sits within metres of windows in a dense city, so plant noise reaches more people than any single source.
  • Open plan Distraction distance, not reverberation time. Ceiling absorption plus screens at the desk.

Full specification

Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for office acoustics are on the main product page. This page covers what that means for a project in Hong Kong.

Office and conference room acoustics Acoustic office screens

02 / The build-up

What goes where, from the structure in

  1. Acoustic hanging ceiling baffles in a large open space

    Layer 1

    Ceiling baffles and clouds

    PET felt suspended from the soffit, vertically as baffles or horizontally as clouds. In Hong Kong, central plant, split units and VRF packed into light wells and podium decks close to every flat.

    Mixed with services. Set out around ducts, trays and lighting rather than fighting them, coordinated from your reflected ceiling plan.

  2. PET acoustic felt wall panels in office interior

    Layer 2

    PET felt acoustic panels

    A rigid non-woven panel pressed from 100% polyester fibre, a large part of it recycled. In Hong Kong, church buildings, halls and function rooms are compact hard volumes carrying amplified speech.

    Over a porous backing. Panel over mineral or PET backing where the room needs genuine low mid control.

  3. SoundBlanket mass loaded vinyl soundproofing membrane used in projects in Abu Dhabi

    Layer 3

    SoundBlanket mass loaded vinyl

    A limp, high density sheet that adds mass to a partition, floor or duct without adding depth. In Hong Kong, school buildings are compact and hard surfaced with very intensive use and no spare volume.

    Wall, decoupled. Independent stud, membrane between the boards, cavity absorption, two boards. The membrane is one part of a system, never the whole answer.

Architects working in Hong Kong usually need the build-up before the product. We will draw the section and mark what does the work. See how we support architects.

03 / In this market

What decides the build-up in Hong Kong

  • Depth is the expensive part

    Every millimetre a wall grows into the room is paid for at Hong Kong rates. A dense thin membrane usually beats a thicker framed build-up here on total cost.

  • Concrete towers, live rooms

    The structure blocks a great deal already. The problem is hard interiors and impact through slabs rather than airborne transfer.

  • Plant on every roof and podium

    Cooling plant sits within metres of windows in a dense city, so plant noise reaches more people than any single source.

  • The port is right here

    Direct sea into Hong Kong keeps the chain short and the landed cost predictable.

  • Plant and HVAC

    Central plant, split units and VRF packed into light wells and podium decks close to every flat.

04 / Room by room

Room by room, on a typical Hong Kong job

  • Office ceiling with acoustic clouds and baffles

    Open plan

    Distraction distance, not reverberation time. Ceiling absorption plus screens at the desk. Every millimetre a wall grows into the room is paid for at Hong Kong rates. A dense thin membrane usually beats a thicker framed build-up here on total cost.

  • Acoustic wall panels in office

    Meeting rooms

    Privacy between rooms. That is partition and door work, not panels. The structure blocks a great deal already. The problem is hard interiors and impact through slabs rather than airborne transfer.

  • Office acoustic carpet tiles and rugs

    Cabins and calls

    Short RT so a call sounds clean. A small amount of well placed absorber. Cooling plant sits within metres of windows in a dense city, so plant noise reaches more people than any single source.

Designers get colour, pattern and CNC options with the absorption figure attached to each. See how we work with interior designers.

04 / Climate and durability

Durability in Hong Kong, before acoustics is discussed

Hong Kong is hot summers, mild winters and a distinct wet season, and that narrows the material list before acoustics is discussed.

PET felt handles the wet months without absorbing moisture or feeding mould. Timber and wood wool want a ventilated cavity and a stable indoor RH.

The failure we design against here is wet-season humidity behind linings.

Where a consultant is already engaged on a Hong Kong project, we supply to their specification and send the test reports rather than describing them. More on working with acoustic consultants.

06 / Before you buy

What we watch go wrong on jobs like this

  • Lining every wall while leaving the ceiling bare

    A treated wall under a bare hard ceiling gives you a fraction of the reduction you paid for, and the room still sounds wrong.

  • Treating a privacy problem with absorption

    Nobody has ever achieved speech privacy with a panel. Privacy needs mass, a sealed head detail and a door that actually closes.

  • Glass cabins specified without a door and head detail

    A gap undoes the partition it sits in. Sealing is the cheapest line on the quote and the first one to get cut.

  • Treating it as a generic Hong Kong job

    Every millimetre a wall grows into the room is paid for at Hong Kong rates. A dense thin membrane usually beats a thicker framed build-up here on total cost.

05 / Logistics

What the route into Hong Kong actually looks like

Supply into Hong Kong
Ships fromPalwal, Haryana, India
Arrives atHong Kong, then a short road run to site
Dispatch4 to 7 working days
FreightSea into Hong Kong
SupportDrawings, build-ups, BOQ and material that arrives complete

Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.

Sea freight direct into Hong Kong, then a short road run to site. Air freight for samples and urgent quantities.

FAQ

Questions from Hong Kong projects

What makes office acoustics and soundproofing different in Hong Kong?

Central plant, split units and VRF packed into light wells and podium decks close to every flat. Every millimetre a wall grows into the room is paid for at Hong Kong rates. A dense thin membrane usually beats a thicker framed build-up here on total cost.

Where should the budget go first on a Hong Kong project?

Open plan. Distraction distance, not reverberation time. Ceiling absorption plus screens at the desk. Meeting rooms. Privacy between rooms. That is partition and door work, not panels.

Do you have an office or installation team in Hong Kong?

No. We manufacture in India and supply into Hong Kong. We give you drawings, build-ups, a BOQ and material that arrives complete, and we will tell you plainly when a job needs a local contractor we cannot be.

How does material get to a Hong Kong site?

ships from: Palwal, Haryana, India, arrives at: Hong Kong, then a short road run to site, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.

What goes wrong most often on this kind of project?

Lining every wall while leaving the ceiling bare. Treating a privacy problem with absorption.

What do you need from us to quote?

A plan, a section through the critical partition or ceiling, and what the room is for. From that we can give a build-up and a BOQ rather than a price per square foot.

Next step

Send the drawings, get a straight answer