Manufactured in India, supplied in Dublin
Wooden slat acoustic panels in Dublin
We manufacture wooden slat acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Dublin. Made at our own plant in India and shipped straight into Dublin Port, which sits inside the city, so the road leg to most sites is measured in minutes.
- Substrate
- MDF, FR MDF, HDF or HDHMR
- Patterns
- 13-3, 14-2, 28-4 and 59-5
- Panel sizes
- 2440 x 192 mm and 2440 x 128 mm
- Thickness
- 14, 16 and 18 mm
- Coverage
- 96 sq ft per unit
- Lead time
- Longer than felt
- Minimum order
- 500 sq ft, about 46 sq m
- EN 13501-1 Class B s1 d0 on FR substrate
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
We make this ourselves and ship it to you. No local branch, no borrowed certifications, no dealer margin. One batch across the whole order, and an honest answer when the product is wrong for the problem.
01 / What it is
The product, described honestly, for a Dublin brief
Timber slats on an acoustic backing. The slats are the finish and the rhythm, the backing does the absorbing. Used where the room has to look considered rather than treated.
Work reaching us from Dublin is mostly build-to-rent apartments, Georgian conversions, docklands offices, pubs and venues, clinics.
Terraced and semi-detached housing with block party walls and timber upper floors. Apartment stock is concrete with hard finishes throughout.
- Slats on felt backing The standard. Absorption comes from the backing behind the gaps, so the slat gap ratio is an acoustic decision, not only a visual one.
- Slats on a cavity Backing plus an air gap behind moves absorption lower, which matters in music rooms.
- Feature wall only Slats where they are seen, plain felt elsewhere, to hold the budget where it shows.
- What it will not do A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for wooden slat panels are on the main product page. This page covers what that means for a project in Dublin.
02 / Specification
Published specification, identical wherever we ship it
Nothing below changes by location. The decisions that do change are grade, thickness and how the material is mounted, and those are covered further down.
- MDFStandard. Dry interiors, general commercial
- FR MDFFire rated. Public buildings and anywhere the specification calls for a class
- HDHMRMoisture resistant. Humid climates and rooms that see damp
| Substrate | MDF, FR MDF, HDF or HDHMR |
|---|---|
| Patterns | 13-3, 14-2, 28-4 and 59-5 |
| Panel sizes | 2440 x 192 mm and 2440 x 128 mm |
| Thickness | 14, 16 and 18 mm |
| Coverage | 96 sq ft per unit |
| Fire class | EN 13501-1 Class B s1 d0 on FR substrate |
Where a consultant is already engaged on a Dublin project, we supply to their specification and send the test reports rather than describing them. More on working with acoustic consultants.
03 / On the ground
What we see driving Dublin briefs
- The port is in the city
Containers land at Dublin Port and are on site the same day. That is the practical reason a factory in India can compete here on landed cost and on timing.
- Build-to-rent party walls
Thousands of units built to the same separating detail. When that detail underperforms, it underperforms in every flat, so it is worth getting right on the drawing.
- Georgian conversions
High ceilings, lath and plaster, timber floors and protected fabric. Everything has to be done internally and shallow, and often reversibly.
- Late trading under homes
Pubs and venues now sit beneath apartments that were not there ten years ago. The low end and the footfall are what generate the complaints.
- Assembly and performance rooms
Church buildings, parish halls and school halls carry speech and music in the same hard volume.
For a Dublin practice, the useful thing is a detail you can put in a drawing set, not a brochure. See how we support architects.
04 / Conditions
Why the climate in Dublin changes the material, not the target
Dublin is cool and damp, with long heating seasons and cold external walls, and that narrows the sensible material list before acoustics is even discussed.
Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would.
The risk we design against here is condensation behind linings in older, poorly insulated stock.
Designers get colour, pattern and CNC options with the absorption figure attached to each. See how we work with interior designers.
05 / Getting it there
Supply into Dublin, start to site
| Ships from | Palwal, Haryana, India |
|---|---|
| Arrives at | Dublin Port, minutes from most city sites |
| Dispatch | 4 to 7 working days |
| Freight | Sea into Dublin Port |
| Packing | Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry. |
| Lead time | Longer than felt. Confirmed against the pattern and substrate at quote stage. |
Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.
Sea freight direct into Dublin Port, then a short road run to site. Air freight for samples and urgent quantities.
The same 500 sq ft minimum applies on export.
| Any specification | 500 sq ft, about 46 sq m |
|---|
One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order.
06 / Before you buy
What we will tell you that a reseller will not
-
The wrong product for the problem
A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
-
Square footage quoted before the room is understood
Anyone can price a wall. Working out how much material the room actually needs usually reduces the order, which is why not everyone does it.
-
A claim of being local to Dublin
We manufacture in India and supply here. We do not run an office in this city and we will not pretend to, because you would find out on the first site visit.
Dublin: questions we are actually asked
Are these wooden slat acoustic panels made in Dublin?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Dublin as the manufacturer rather than through a dealer. Made at our own plant in India and shipped straight into Dublin Port, which sits inside the city, so the road leg to most sites is measured in minutes. You buy at factory prices with one consistent batch across the order.
Why would a Dublin build-up differ from anywhere else?
Containers land at Dublin Port and are on site the same day. That is the practical reason a factory in India can compete here on landed cost and on timing. Thousands of units built to the same separating detail. When that detail underperforms, it underperforms in every flat, so it is worth getting right on the drawing. Those two things move the build-up far more than the panel figure does.
Is this the right material for Dublin conditions?
Dublin is cool and damp, with long heating seasons and cold external walls. Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would. The failure we design against here is condensation behind linings in older, poorly insulated stock.
How quickly can material reach a site in Dublin?
ships from: Palwal, Haryana, India, arrives at: Dublin Port, minutes from most city sites, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.
What should you not buy wooden slat acoustic panels for?
A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
What is the minimum order and how is it packed?
The same 500 sq ft minimum applies on export. Any specification, 500 sq ft, about 46 sq m. One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order. Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.
Next step
Drawings in, BOQ and a delivered date out
One drawing gets you a proper answer. Build-up, quantities, a delivered date, and an honest note on anything we think is the wrong approach.