Manufactured in India, supplied in Vancouver
PET felt acoustic panels in Vancouver
We manufacture PET felt acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Vancouver. Made at our own plant in India and shipped straight into Vancouver, so the container lands at the city rather than railing across the country.
- Material
- 100% PET non-woven, no added binder
- Thickness
- 9, 12, 18 and 24 mm standard, tolerance plus or minus 5 percent
- Custom thickness
- 4 to 24 mm
- Panel size
- 1220 x 2440 mm standard, 4 x 8 ft
- Maximum size
- 2440 x 4270 mm, 2.44 x 4.27 m, 8 x 14 ft
- Lead time
- 4 to 7 working days for standard colours and thicknesses
- Minimum order
- From 10 panels
- ASTM C423
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
Manufacturer, not reseller. We hold no local approvals and will not imply we do. You get the price the factory quotes, material that matches across a large order, and advice that sometimes talks you out of a purchase.
01 / The material
What this material is and where it earns its place in Vancouver
A rigid non-woven panel pressed from 100% polyester fibre, a large part of it recycled. It absorbs mid and high frequency energy and finishes as the visible surface, so it is both the acoustic layer and the finish.
Work reaching us from Vancouver is mostly mass timber and light frame housing, condominium towers, offices, schools, studios, clinics.
Timber frame with gypsum board in low rise, concrete in towers. Condominium party walls and floors generate most complaints, and impact noise through a concrete slab needs a resilient layer, not a panel.
- Direct to wall Panel bonded or mechanically fixed flat to the substrate. Simplest, and the weakest at low frequency.
- On a 25 to 50 mm air gap The same panel on battens. The air gap moves absorption down in frequency at no extra material cost, and is the cheapest improvement available.
- Over a porous backing Panel over mineral or PET backing where the room needs genuine low mid control.
- What it will not do It absorbs. It does not block.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for PET felt panels are on the main product page. This page covers what that means for a project in Vancouver.
02 / Specification sheet
One specification sheet, the same in every market
Nothing below changes by location. The decisions that do change are grade, thickness and how the material is mounted, and those are covered further down.
- EchoCore 151500 GSM. Offices, classrooms, general commercial
- EchoPro 181800 GSM. Studios, auditoria, rooms with a written RT target
- EchoMax 222200 GSM. High occupancy and high level spaces
| Material | 100% PET non-woven, no added binder |
|---|---|
| Thickness | 9, 12, 18 and 24 mm standard, tolerance plus or minus 5 percent |
| Custom thickness | 4 to 24 mm |
| Panel size | 1220 x 2440 mm standard, 4 x 8 ft |
| Maximum size | 2440 x 4270 mm, 2.44 x 4.27 m, 8 x 14 ft |
| Density range | 1200 to 3600 GSM |
| NRC | 0.30 at 9 mm, rising with thickness and air gap |
| Test standard | ASTM C423 |
On a Vancouver job with a consultant involved, our part is material that matches the submitted data. See working with acoustic consultants.
03 / In this market
What decides the build-up in Vancouver
- Damp, mild climate
PET felt does not absorb moisture, shed fibre or feed mould, which suits cold external walls and sealed rooms.
- Timber is light
Mass timber looks solid and performs nothing like concrete at low frequency. Added mass and a decoupled layer do the work, not more absorption.
- Rain on the roof
Metal and membrane roofs over open volumes turn heavy rain into a noise source worth designing for rather than discovering.
- The port is right here
Direct sea into Vancouver means no rail leg across the country, so the landed cost and the date are both easier to hold.
- School and campus buildings
School buildings run hard floors and lay-in tile with long heating seasons and sealed envelopes, so rooms stay live and mechanical noise is always present.
For a Vancouver practice, the useful thing is a detail you can put in a drawing set, not a brochure. See how we support architects.
04 / Climate
Durability in Vancouver, before acoustics is discussed
Vancouver is cool and damp, with long heating seasons and cold external walls, and that narrows the sensible material list before acoustics is even discussed.
Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would.
The risk we design against here is condensation behind linings in older, poorly insulated stock.
Interior designers tend to arrive with the look already decided. We will tell you which finish gets there without losing the acoustics. See how we work with interior designers.
05 / Supply
What the route into Vancouver actually looks like
| Ships from | Palwal, Haryana, India |
|---|---|
| Arrives at | Vancouver, then a short road run to site |
| Dispatch | 4 to 7 working days |
| Freight | Sea into Vancouver |
| Packing | Palletised flat and film wrapped, cut sheets interleaved. Packing list and weights issued with the quote. |
| Lead time | 4 to 7 working days for standard colours and thicknesses. Grooved and custom colours take longer, and we say so before you order. |
Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.
Sea freight direct into Vancouver, then a short road run to site. Air freight for samples and urgent quantities.
200 panels for a trial order, in any mix of thickness, GSM and colour. Beyond a trial we would rather quote a container load, because the price per panel and the freight per panel both fall sharply and a part load pays for space it does not use.
| Trial order | 200 panels, 6,400 sq ft, mixed thickness, GSM and colour |
|---|---|
| Recommended | Full container, for the best price per panel and the lowest freight per panel |
A panel is 1220 x 2440 mm, which is 32 sq ft.
06 / Before you buy
Where this goes wrong, said plainly
-
The wrong product for the problem
It absorbs. It does not block. A PET panel on a shared wall will make the room sound better and will not stop the neighbour being heard. If the brief is stopping noise passing through a wall or floor, the answer is mass and decoupling, and we will say so before quoting.
-
Coverage bought instead of a target
Lining every surface is a purchase, not a result. We would rather calculate the area against a reverberation target and sell you less of it.
-
A claim of being local to Vancouver
We manufacture in India and supply here. We do not run an office in this city and we will not pretend to, because you would find out on the first site visit.
Vancouver: questions we are actually asked
Do you manufacture PET felt acoustic panels in Vancouver?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Vancouver as the manufacturer rather than through a dealer. Made at our own plant in India and shipped straight into Vancouver, so the container lands at the city rather than railing across the country. You buy at factory prices with one consistent batch across the order.
What decides the specification for a Vancouver project?
Mass timber looks solid and performs nothing like concrete at low frequency. Added mass and a decoupled layer do the work, not more absorption. Metal and membrane roofs over open volumes turn heavy rain into a noise source worth designing for rather than discovering. Those two things move the build-up far more than the panel figure does.
Will this material last in the Vancouver climate?
Vancouver is cool and damp, with long heating seasons and cold external walls. Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would. The failure we design against here is condensation behind linings in older, poorly insulated stock.
How quickly can material reach a site in Vancouver?
ships from: Palwal, Haryana, India, arrives at: Vancouver, then a short road run to site, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.
When are PET felt acoustic panels the wrong purchase?
It absorbs. It does not block. A PET panel on a shared wall will make the room sound better and will not stop the neighbour being heard. If the brief is stopping noise passing through a wall or floor, the answer is mass and decoupling, and we will say so before quoting.
What quantity do we have to order, and in what packaging?
200 panels for a trial order, in any mix of thickness, GSM and colour. Beyond a trial we would rather quote a container load, because the price per panel and the freight per panel both fall sharply and a part load pays for space it does not use. Trial order, 200 panels, 6,400 sq ft, mixed thickness, GSM and colour. Recommended, Full container, for the best price per panel and the lowest freight per panel. A panel is 1220 x 2440 mm, which is 32 sq ft. Palletised flat and film wrapped, cut sheets interleaved. Packing list and weights issued with the quote.
Next step
Drawings in, BOQ and a delivered date out
We quote from drawings, not from a square foot rate. Send a plan and the section through the critical wall or ceiling and you will get something you can actually build from.