Home > Prague > Wooden slat acoustic panels

Acoustic wooden slat wall and ceiling in a premium auditorium

Manufactured in India, supplied in Prague

Wooden slat acoustic panels in Prague

We manufacture wooden slat acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Prague. Made at our own plant in India and shipped into Hamburg, then rail and road into the city, with the inland leg written into the dates we quote.

Substrate
MDF, FR MDF, HDF or HDHMR
Patterns
13-3, 14-2, 28-4 and 59-5
Panel sizes
2440 x 192 mm and 2440 x 128 mm
Thickness
14, 16 and 18 mm
Coverage
96 sq ft per unit
Lead time
Longer than felt
Minimum order
500 sq ft, about 46 sq m
  • EN 13501-1 Class B s1 d0 on FR substrate
  • Made at our own plant, Palwal, Haryana, India
  • One batch across the order, no blending between runs

We make this ourselves and ship it to you. No local branch, no borrowed certifications, no dealer margin. One batch across the whole order, and an honest answer when the product is wrong for the problem.

01 / The material

What this is, and what it changes in a Prague room

Timber slats on an acoustic backing. The slats are the finish and the rhythm, the backing does the absorbing. Used where the room has to look considered rather than treated.

Work reaching us from Prague is mostly hotel conversions, apartments, production and studio spaces, offices, restaurants, clinics.

Panel block housing has concrete walls with good mass but no impact isolation, while older masonry stock has timber floors that pass footfall.

  • Slats on felt backing The standard. Absorption comes from the backing behind the gaps, so the slat gap ratio is an acoustic decision, not only a visual one.
  • Slats on a cavity Backing plus an air gap behind moves absorption lower, which matters in music rooms.
  • Feature wall only Slats where they are seen, plain felt elsewhere, to hold the budget where it shows.
  • What it will not do A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

Full specification

Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for wooden slat panels are on the main product page. This page covers what that means for a project in Prague.

Wooden slat acoustic panels SoundaXe wooden panels

02 / Specification

The published figures, unchanged by location

Nothing below changes by location. The decisions that do change are grade, thickness and how the material is mounted, and those are covered further down.

  • MDFStandard. Dry interiors, general commercial
  • FR MDFFire rated. Public buildings and anywhere the specification calls for a class
  • HDHMRMoisture resistant. Humid climates and rooms that see damp
Wooden slat acoustic panels: published specification
SubstrateMDF, FR MDF, HDF or HDHMR
Patterns13-3, 14-2, 28-4 and 59-5
Panel sizes2440 x 192 mm and 2440 x 128 mm
Thickness14, 16 and 18 mm
Coverage96 sq ft per unit
Fire classEN 13501-1 Class B s1 d0 on FR substrate

If a consultant has set the target, we will quote against their figures rather than ours, and stay out of the scope they own. More on working with acoustic consultants.

03 / In this market

What the buildings in Prague do to the specification

  • Protected buildings, internal fixes only

    In the centre you often cannot alter the structure or the facade. The work has to be internal, shallow and ideally reversible, which rules out most thick framed systems.

  • Conversions into guest rooms

    Old buildings divided into hotel rooms and short lets put beds either side of walls that were never separating walls. Door and corridor details cause more complaints than anything else.

  • A production city

    Stages, edit rooms and post production spaces need the shell to isolate before anything else is decided. There is no partial credit on a room like that.

  • Hard stone, long reverberation

    Stone, plaster and tile in tall rooms hold sound for a long time. Speech stops being intelligible well before the room sounds obviously wrong.

  • Assembly and performance rooms

    Concert halls, church buildings and civic rooms are long-decay volumes in stone and plaster.

Architects working in Prague usually need the build-up before the product. We will draw the section and mark what does the work. See how we support architects.

04 / Climate

Why the climate in Prague changes the material, not the target

Prague is cool and damp, with long heating seasons and cold external walls, and that narrows the sensible material list before acoustics is even discussed.

Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would.

The risk we design against here is condensation behind linings in older, poorly insulated stock.

Interior designers tend to arrive with the look already decided. We will tell you which finish gets there without losing the acoustics. See how we work with interior designers.

05 / Logistics

Supply into Prague, start to site

Supply into Prague
Ships fromPalwal, Haryana, India
Arrives atHamburg, then rail and road into Prague
Dispatch4 to 7 working days
FreightSea via Hamburg
PackingBraced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.
Lead timeLonger than felt. Confirmed against the pattern and substrate at quote stage.

Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.

Sea freight into Hamburg, then rail and road into Prague. Air freight for samples and urgent quantities.

The same 500 sq ft minimum applies on export.

Minimum order, wooden slat acoustic panels
Any specification500 sq ft, about 46 sq m

One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order.

06 / Worth knowing

Four honest warnings before you buy

  • The wrong product for the problem

    A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

  • Square footage quoted before the room is understood

    Anyone can price a wall. Working out how much material the room actually needs usually reduces the order, which is why not everyone does it.

  • A claim of being local to Prague

    We manufacture in India and supply here. We do not run an office in this city and we will not pretend to, because you would find out on the first site visit.

FAQ

Prague: questions we are actually asked

Is there a Prague factory behind this product?

No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Prague as the manufacturer rather than through a dealer. Made at our own plant in India and shipped into Hamburg, then rail and road into the city, with the inland leg written into the dates we quote. You buy at factory prices with one consistent batch across the order.

What do you look at first on a Prague enquiry?

In the centre you often cannot alter the structure or the facade. The work has to be internal, shallow and ideally reversible, which rules out most thick framed systems. Old buildings divided into hotel rooms and short lets put beds either side of walls that were never separating walls. Door and corridor details cause more complaints than anything else. Those two things move the build-up far more than the panel figure does.

Does Prague weather shorten the life of this material?

Prague is cool and damp, with long heating seasons and cold external walls. Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would. The failure we design against here is condensation behind linings in older, poorly insulated stock.

When would material land on a Prague site?

ships from: Palwal, Haryana, India, arrives at: Hamburg, then rail and road into Prague, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.

Where do wooden slat acoustic panels fail to help?

A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

Is there a minimum order, and how does it arrive?

The same 500 sq ft minimum applies on export. Any specification, 500 sq ft, about 46 sq m. One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order. Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.

Next step

Send the drawings, get a straight answer

One drawing gets you a proper answer. Build-up, quantities, a delivered date, and an honest note on anything we think is the wrong approach.