Home > New York > Acoustic panels

Acoustic Panel Manufacturer Supplying in Abu Dhabi

Manufactured in India, supplied in New York

Acoustic panels in New York

We manufacture acoustic panels at our own plant at Palwal in Haryana, India, and supply them into New York. Made at our own plant in India and shipped into the Port of New York and New Jersey, so the container lands at the city rather than crossing the country.

Plain PET felt
9 to 24 mm, 1220 x 2440 mm standard, up to 2440 x 4270 mm, 1200 to 3600 GSM
Printed felt
1800 x 900 mm, image printed into the felt rather than onto a facing
Grooved panels
Cut pattern in PET felt, adds visual rhythm without changing the absorber
Test standard
ASTM C423
Lead time
4 to 7 working days standard
Minimum order
From 10 panels
  • ASTM C423
  • Made at our own plant, Palwal, Haryana, India
  • One batch across the order, no blending between runs

We are the manufacturer. There is no local office and we do not claim approvals we do not hold. What you get is factory pricing, one consistent batch across the order, and a straight answer on what the material will and will not do.

01 / The material

What you are buying, and what it fixes in New York

The full absorber range rather than one product: plain PET felt, printed felt, grooved panels and fabric finishes, chosen by how the room is used and how it has to look.

Work reaching us from New York is mostly pre-war apartments, brownstones, offices, studios, restaurants, clinics, schools.

American homes are timber frame with gypsum board on both faces, so a party wall or a basement ceiling has almost no mass. Adding a second leaf with a limp membrane between does more than any amount of surface treatment.

  • Wall array Panels placed at first reflection points rather than spread evenly. Fewer panels, better result.
  • Ceiling first In most rooms the ceiling is the largest untreated surface and the cheapest square metre of result.
  • Mixed finish Plain felt where it is out of eye line, printed or grooved where it is seen.
  • What it will not do Coverage is not the target, reverberation time is. Lining every surface wastes money and can leave a room sounding dead and unpleasant.

Full specification

Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for our acoustic panel range are on the main product page. This page covers what that means for a project in New York.

PET felt acoustic panels Printed acoustic felt panels Grooved PET panels

02 / Specification

The numbers, and they do not move by city

Nothing below changes by location. The decisions that do change are grade, thickness and how the material is mounted, and those are covered further down.

  • EchoCore 151500 GSM. General commercial
  • EchoPro 181800 GSM. Rooms with a written RT target
  • EchoMax 222200 GSM. High occupancy and high level spaces
Acoustic panels: published specification
Plain PET felt9 to 24 mm, 1220 x 2440 mm standard, up to 2440 x 4270 mm, 1200 to 3600 GSM
Printed felt1800 x 900 mm, image printed into the felt rather than onto a facing
Grooved panelsCut pattern in PET felt, adds visual rhythm without changing the absorber
Test standardASTM C423

Where a consultant is already engaged on a New York project, we supply to their specification and send the test reports rather than describing them. More on working with acoustic consultants.

03 / Local conditions

What we see driving New York briefs

  • Boards decide the build-up

    Co-op and condo rules on floor coverings and separating construction usually set the requirement before any acoustic target does. Get the rule first, then design to it.

  • Pre-war buildings, timber floors

    Older stock passes footfall straight down through the joists. A resilient layer under the finish does more than anything applied to the ceiling below.

  • Depth is expensive here

    Floor area costs enough that a wall growing a hundred millimetres into the room is a real number. Thin and effective beats thick and theoretical.

  • Subway and street

    Ground level and underground rail put low frequency into the structure. Panels on a wall will not touch it and we will say so.

  • School and campus buildings

    Public school buildings run long corridors with hard floors and lay-in tile ceilings that were chosen for cost, not for speech. Classroom reverberation and corridor spill are the two complaints, and both respond to ceiling area rather than wall panels.

  • The studio and content scene

    Home and project studios go into basements and converted garages with equipment budgets far ahead of the building. The room leaks to the floor above long before it sounds wrong inside.

If you are specifying for a New York project, we can give you a section, a BOQ and the honest limits of each layer. See how we support architects.

04 / Climate

Durability in New York, before acoustics is discussed

New York is mild summers and cold, wet winters, and that narrows the sensible material list before acoustics is even discussed.

Cold external walls and long heating seasons make condensation behind a lining the thing to design out. PET felt is unaffected by damp air.

The risk we design against here is condensation and cold bridging behind new linings.

If the visual is fixed and the room still has to perform, that is a solvable problem and a conversation worth having early. See how we work with interior designers.

05 / Getting it there

How material reaches a New York site

Supply into New York
Ships fromPalwal, Haryana, India
Arrives atPort of New York and New Jersey, then a short road run
Dispatch4 to 7 working days
FreightSea into New York
PackingPalletised flat and film wrapped. Printed panels interleaved and corner protected.
Lead time4 to 7 working days standard. Printed and grooved take longer.

Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.

Sea freight into the Port of New York and New Jersey, then a short road run to site. Air freight for samples and urgent quantities.

200 panels for a trial order, in any mix of thickness, GSM and colour. Beyond a trial we would rather quote a container load.

Minimum order, acoustic panels
Trial order200 panels, 6,400 sq ft, mixed thickness, GSM and colour
RecommendedFull container

A panel is 1220 x 2440 mm, which is 32 sq ft.

06 / Read this first

The things worth knowing before you place the order

  • The wrong product for the problem

    Coverage is not the target, reverberation time is. Lining every surface wastes money and can leave a room sounding dead and unpleasant. We would rather calculate the area than sell the wall.

  • A number chased without a measurement

    If nobody has measured the room or set a target, the specification is a guess with a decimal point in it. We will ask for the target before we quote the quantity.

  • Local approvals that nobody actually holds

    We hold no New York certification and we will not borrow one. The test data we publish is ours, and we will send the reports rather than describe them.

07 / In projects

The material in real interiors

Acoustic foam panels
Acoustic foam panels
Acoustic foam panels
Acoustic foam panels
Custom acoustic panels
Custom acoustic panels
Acoustic testing & QC
Acoustic testing & QC
Client 1
Client 1
Client 2
Client 2
FAQ

New York: questions we are actually asked

Is there a New York factory behind this product?

No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into New York as the manufacturer rather than through a dealer. Made at our own plant in India and shipped into the Port of New York and New Jersey, so the container lands at the city rather than crossing the country. You buy at factory prices with one consistent batch across the order.

What changes the specification on a New York job?

Co-op and condo rules on floor coverings and separating construction usually set the requirement before any acoustic target does. Get the rule first, then design to it. Older stock passes footfall straight down through the joists. A resilient layer under the finish does more than anything applied to the ceiling below. Those two things move the build-up far more than the panel figure does.

Will this material last in the New York climate?

New York is mild summers and cold, wet winters. Cold external walls and long heating seasons make condensation behind a lining the thing to design out. PET felt is unaffected by damp air. The failure we design against here is condensation and cold bridging behind new linings.

How quickly can material reach a site in New York?

ships from: Palwal, Haryana, India, arrives at: Port of New York and New Jersey, then a short road run, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.

What should you not buy acoustic panels for?

Coverage is not the target, reverberation time is. Lining every surface wastes money and can leave a room sounding dead and unpleasant. We would rather calculate the area than sell the wall.

What is the minimum order and how is it packed?

200 panels for a trial order, in any mix of thickness, GSM and colour. Beyond a trial we would rather quote a container load. Trial order, 200 panels, 6,400 sq ft, mixed thickness, GSM and colour. Recommended, Full container. A panel is 1220 x 2440 mm, which is 32 sq ft. Palletised flat and film wrapped. Printed panels interleaved and corner protected.

Next step

Send the drawings, get a straight answer