Two duties at once: privacy where confidential conversations happen, and a lower noise floor where people are trying to rest. Hygiene and cleanability rule out a lot of products before acoustics is even discussed. Mechanical ventilation with heat recovery is standard in newer stock, so duct-borne noise and terminal unit noise are the sources rather than open windows.
- Consulting room privacy
- Speech privacy between rooms, which is partition, door and ceiling void work.
- Ward noise floor
- Alarms, trolleys and staff conversation in hard corridors. Absorption at the ceiling.
- Cleanability
- Non shedding, non absorbent surfaces that survive a cleaning regime.
- Quote
- From a plan and a section, within 48 hours
01 / What it is
The material, and what it actually does on a Munich job
Two duties at once: privacy where confidential conversations happen, and a lower noise floor where people are trying to rest. Hygiene and cleanability rule out a lot of products before acoustics is even discussed.
Mechanical ventilation with heat recovery is standard in newer stock, so duct-borne noise and terminal unit noise are the sources rather than open windows.
Work reaching us from Munich is mostly apartments and villas, corporate floors, studios, hotels, clinics, schools.
- Altbau above, concrete below A stucco ceilinged Altbau flat and a post-war concrete block need different answers to the same complaint. We ask which one you are in before we quote anything.
- Specified, with numbers attached Send us the acoustician report and the target values. We will tell you what our build-up gets to and where it falls short, in writing, before you commit.
- Floor area is expensive here Every centimetre the wall grows into the room is money. A dense membrane plus a resilient layer usually beats a thick framed build-up on both cost and depth.
- Consulting room privacy Speech privacy between rooms, which is partition, door and ceiling void work.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for healthcare acoustics are on the main product page. This page covers what that means for a project in Munich.
02 / The build-up
What goes where, from the structure in
-

Layer 1
PET felt acoustic panels
A rigid non-woven panel pressed from 100% polyester fibre, a large part of it recycled. In Munich, mechanical ventilation with heat recovery is standard in newer stock, so duct-borne noise and terminal unit noise are the sources rather than open windows.
Direct to wall. Panel bonded or mechanically fixed flat to the substrate. Simplest, and the weakest at low frequency.
-

Layer 2
Acoustic carpet and rugs
A tile carpet with a dense polyester face on a felt backing. In Munich, concert halls, church buildings and civic Saal spaces are long-reverberation rooms where any intervention has to be reversible and visually disciplined.
Loose lay on tackifier. Tiles lifted individually for access under a raised floor, which is why tile beats broadloom in an office.
-

Layer 3
Acoustic panels
The full absorber range rather than one product: plain PET felt, printed felt, grooved panels and fabric finishes, chosen by how the room is used and how it has to look. In Munich, school and university buildings are built to a high thermal standard with hard, cleanable surfaces. Speech clarity in classrooms and long corridors is where the acoustic budget goes.
Wall array. Panels placed at first reflection points rather than spread evenly. Fewer panels, better result.
Architects working in Munich usually need the build-up before the product. We will draw the section and mark what does the work. See how we support architects.
03 / In this market
What decides the build-up in Munich
- Altbau above, concrete below
A stucco ceilinged Altbau flat and a post-war concrete block need different answers to the same complaint. We ask which one you are in before we quote anything.
- Specified, with numbers attached
Send us the acoustician report and the target values. We will tell you what our build-up gets to and where it falls short, in writing, before you commit.
- Floor area is expensive here
Every centimetre the wall grows into the room is money. A dense membrane plus a resilient layer usually beats a thick framed build-up on both cost and depth.
- Corporate and studio work
Head office floors, media rooms and production studios around the city want measured performance and a finish that survives a design review.
- Plant and HVAC
Mechanical ventilation with heat recovery is standard in newer stock, so duct-borne noise and terminal unit noise are the sources rather than open windows.
04 / Room by room
Where the money goes on a Munich project
-

Consulting room privacy
Speech privacy between rooms, which is partition, door and ceiling void work. A stucco ceilinged Altbau flat and a post-war concrete block need different answers to the same complaint. We ask which one you are in before we quote anything.
- PET felt acoustic panels, 100% PET non-woven, no added binder
- Ceiling baffles and clouds, 9 to 24 mm
- Acoustic panels, Cut pattern in PET felt, adds visual rhythm without changing the absorber
-

Ward noise floor
Alarms, trolleys and staff conversation in hard corridors. Absorption at the ceiling. Send us the acoustician report and the target values. We will tell you what our build-up gets to and where it falls short, in writing, before you commit.
- PET felt acoustic panels, 9, 12, 18 and 24 mm standard, tolerance plus or minus 5 percent
- Ceiling baffles and clouds, Made to the drawing, standard and custom
- Acoustic panels, ASTM C423
-

Cleanability
Non shedding, non absorbent surfaces that survive a cleaning regime. Every centimetre the wall grows into the room is money. A dense membrane plus a resilient layer usually beats a thick framed build-up on both cost and depth.
- PET felt acoustic panels, 4 to 24 mm
- Ceiling baffles and clouds, Both faces work, which is why suspended area outperforms the same area laid flat
- Acoustic panels, 9 to 24 mm, 1220 x 2440 mm standard, up to 2440 x 4270 mm, 1200 to 3600 GSM
For a Munich interior where the finish leads, we will say plainly what each option costs you acoustically. See how we work with interior designers.
04 / Climate and durability
Durability in Munich, before acoustics is discussed
Munich is cool and damp, with long heating seasons and cold external walls, and that narrows the material list before acoustics is discussed.
Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would.
The failure we design against here is condensation behind linings in older, poorly insulated stock.
On a Munich job with a consultant involved, our part is material that matches the submitted data. See working with acoustic consultants.
06 / Worth knowing
The six errors that cost the most
-
Fabric wrapped products in a clinical area
Enclose the machine, break the vibration path, then deal with what is left. Doing it in the other order costs more and achieves less.
-
Absorption used where privacy was the requirement
Nobody has ever achieved speech privacy with a panel. Privacy needs mass, a sealed head detail and a door that actually closes.
-
Ceiling void left open above a partition
The ceiling is almost always the largest untreated surface, so leaving it out means paying for panels that cannot reach the target.
-
Treating it as a generic Munich job
A stucco ceilinged Altbau flat and a post-war concrete block need different answers to the same complaint. We ask which one you are in before we quote anything.
05 / Route to site
Getting it to Munich, with real dates
| Ships from | Palwal, Haryana, India |
|---|---|
| Arrives at | Hamburg or Bremerhaven, then rail and road south to Bavaria |
| Dispatch | 4 to 7 working days |
| Freight | Sea via Hamburg |
| Support | Drawings, build-ups, BOQ and material that arrives complete |
Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order.
Sea freight into Hamburg or Bremerhaven, then rail and road south. It is a long inland leg and we build it into the dates we give you rather than pretending it is not there.
Questions from Munich projects
What makes hospital and healthcare acoustics different in Munich?
Mechanical ventilation with heat recovery is standard in newer stock, so duct-borne noise and terminal unit noise are the sources rather than open windows. A stucco ceilinged Altbau flat and a post-war concrete block need different answers to the same complaint. We ask which one you are in before we quote anything.
Where should the budget go first on a Munich project?
Consulting room privacy. Speech privacy between rooms, which is partition, door and ceiling void work. Ward noise floor. Alarms, trolleys and staff conversation in hard corridors. Absorption at the ceiling.
Do you have an office or installation team in Munich?
No. We manufacture in India and supply into Munich. We give you drawings, build-ups, a BOQ and material that arrives complete, and we will tell you plainly when a job needs a local contractor we cannot be.
How does material get to a Munich site?
ships from: Palwal, Haryana, India, arrives at: Hamburg or Bremerhaven, then rail and road south to Bavaria, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order.
What goes wrong most often on this kind of project?
Fabric wrapped products in a clinical area. Absorption used where privacy was the requirement.
What do you need from us to quote?
A plan, a section through the critical partition or ceiling, and what the room is for. From that we can give a build-up and a BOQ rather than a price per square foot.
Next step
Tell us the room, we will tell you the build-up