Manufactured in India, supplied in London
Wood wool acoustic panels in London
We manufacture wood wool acoustic panels at our own plant at Palwal in Haryana, India, and supply them into London. Made at our own plant in India, packed for container transit, specified with your drawings before anything ships.
- Panel size
- 1200 x 600 mm
- Thickness
- 20 mm
- Density
- 400 kg per cubic metre
- NRC
- 0.30
- Test standards
- ASTM C-423 and EN ISO 354
- Lead time
- 4 to 7 working days for standard sizes
- Minimum order
- 500 sq ft, about 46 sq m
- ASTM C-423 and EN ISO 354
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
This comes from our own plant, not a trading desk. We do not have an office in your city and we will not invent one. What we can give you is factory pricing, consistent material and a technical answer before you commit.
01 / The product
What this is, and what it changes in a London room
Wood fibre bound into a rigid board with an open texture. Robust, paintable and used where the surface takes knocks, which is why it ends up in schools, sports halls and plant rooms.
Work reaching us from London is mostly flat conversions, offices, studios, bars and restaurants, schools, clinics.
Victorian and Edwardian terraces split into flats share a single brick party wall and a timber joist floor that was never built for two households. Newer stock is concrete with harder finishes.
- Direct fix Mechanically fixed to the soffit or wall. Durable and simple.
- On a cavity Mounted on battens with an air gap, which is where the low mid performance comes from.
- With a porous backing Board over mineral backing where the room needs more than the board alone gives.
- What it will not do At 20 mm it is a mid and high frequency absorber, not a bass solution, and painting it heavily will close the surface and reduce what it does. If a room needs low frequency control, depth or a cavity has to come from somewhere.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for wood wool panels are on the main product page. This page covers what that means for a project in London.
02 / Data sheet
The published figures, unchanged by location
The specification below is the same everywhere we supply, because a specification that changed by city would not be a specification. What changes is which grade and build-up is the right buy, and that is what the rest of this page is about.
- Natural20 mm. Plant rooms, back of house, industrial
- Painted20 mm. Classrooms, halls, visible ceilings
| Panel size | 1200 x 600 mm |
|---|---|
| Thickness | 20 mm |
| Density | 400 kg per cubic metre |
| NRC | 0.30 |
| Test standards | ASTM C-423 and EN ISO 354 |
| Surface burning | Class A to ASTM E84 |
If a consultant has set the target, we will quote against their figures rather than ours, and stay out of the scope they own. More on working with acoustic consultants.
03 / In this market
The London conditions that change the answer
- Rail and Underground rumble
Structure borne, so surface panels do nothing. It needs mass and decoupling in the floor, wall or ceiling first.
- Single brick party walls
A joist floor between two flats was never built for two households. Membrane plus an independent lining, then absorption.
- Night economy neighbours
Soho, Shoreditch, Camden and Clapham venues sit under flats. Bass containment and table-level comfort are two different jobs.
- Damp winters
PET felt does not absorb moisture, shed fibre or feed mould, which matters in older stock with cold wall build-ups.
- Assembly and performance rooms
Church buildings, village and parish halls, and school halls carry speech, music and sport in one long-decay volume.
- School and campus buildings
School buildings mix Victorian halls with post war system build and new academies, so hard floors, high ceilings and long corridors are the constant.
If you are specifying for a London project, we can give you a section, a BOQ and the honest limits of each layer. See how we support architects.
04 / Conditions
Durability in London, before acoustics is discussed
London is cool and damp, with long heating seasons and cold external walls, and that narrows the sensible material list before acoustics is even discussed.
Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would.
The risk we design against here is condensation behind linings in older, poorly insulated stock.
For a London interior where the finish leads, we will say plainly what each option costs you acoustically. See how we work with interior designers.
05 / Route to site
How material reaches a London site
| Ships from | Palwal, Haryana, India |
|---|---|
| Arrives at | Felixstowe, London Gateway or Southampton |
| Dispatch | 4 to 7 working days |
| Freight | Sea and air |
| Packing | Palletised flat, edge protected. Boards are rigid but the edges chip, so they travel protected. |
| Lead time | 4 to 7 working days for standard sizes. |
Standard items dispatch in 4 to 7 working days. Grooved and custom colours take longer, and we say so before you order, not after.
Sea freight to Felixstowe, London Gateway or Southampton. Air freight for samples and urgent quantities. Clearance through your agent or ours.
The same 500 sq ft minimum applies on export.
| Any finish | 500 sq ft, about 46 sq m |
|---|
A panel is 1200 x 600 mm, which is 0.72 sq m or about 7.75 sq ft, so the minimum is roughly 65 panels.
06 / Before you buy
Four honest warnings before you buy
-
The wrong product for the problem
At 20 mm it is a mid and high frequency absorber, not a bass solution, and painting it heavily will close the surface and reduce what it does. If a room needs low frequency control, depth or a cavity has to come from somewhere.
-
Coverage bought instead of a target
Lining every surface is a purchase, not a result. We would rather calculate the area against a reverberation target and sell you less of it.
-
Local approvals that nobody actually holds
We hold no London certification and we will not borrow one. The test data we publish is ours, and we will send the reports rather than describe them.
London: questions we are actually asked
Is there a London factory behind this product?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into London as the manufacturer rather than through a dealer. Made at our own plant in India, packed for container transit, specified with your drawings before anything ships. You buy at factory prices with one consistent batch across the order.
What do you look at first on a London enquiry?
Structure borne, so surface panels do nothing. It needs mass and decoupling in the floor, wall or ceiling first. A joist floor between two flats was never built for two households. Membrane plus an independent lining, then absorption. Those two things move the build-up far more than the panel figure does.
Does London weather shorten the life of this material?
London is cool and damp, with long heating seasons and cold external walls. Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would. The failure we design against here is condensation behind linings in older, poorly insulated stock.
How quickly can material reach a site in London?
ships from: Palwal, Haryana, India, arrives at: Felixstowe, London Gateway or Southampton, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. Grooved and custom colours take longer, and we say so before you order, not after.
When are wood wool acoustic panels the wrong purchase?
At 20 mm it is a mid and high frequency absorber, not a bass solution, and painting it heavily will close the surface and reduce what it does. If a room needs low frequency control, depth or a cavity has to come from somewhere.
Is there a minimum order, and how does it arrive?
The same 500 sq ft minimum applies on export. Any finish, 500 sq ft, about 46 sq m. A panel is 1200 x 600 mm, which is 0.72 sq m or about 7.75 sq ft, so the minimum is roughly 65 panels. Palletised flat, edge protected. Boards are rigid but the edges chip, so they travel protected.
Next step
Send the drawings, get a straight answer
We quote from drawings, not from a square foot rate. Send a plan and the section through the critical wall or ceiling and you will get something you can actually build from.