Manufactured in India, supplied in Florida
Acoustic panels in Florida
We manufacture acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Florida. Made at our own plant in India and shipped into Jacksonville, Miami or Port Everglades, so the container lands in the state rather than crossing the country.
- Plain PET felt
- 9 to 24 mm, 1220 x 2440 mm standard, up to 2440 x 4270 mm, 1200 to 3600 GSM
- Printed felt
- 1800 x 900 mm, image printed into the felt rather than onto a facing
- Grooved panels
- Cut pattern in PET felt, adds visual rhythm without changing the absorber
- Test standard
- ASTM C423
- Lead time
- 4 to 7 working days standard
- Minimum order
- From 10 panels
- ASTM C423
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
This comes from our own plant, not a trading desk. We do not have an office in your city and we will not invent one. What we can give you is factory pricing, consistent material and a technical answer before you commit.
01 / What it is
The product, described honestly, for a Florida brief
The full absorber range rather than one product: plain PET felt, printed felt, grooved panels and fabric finishes, chosen by how the room is used and how it has to look.
Work reaching us from Florida is mostly condominium towers, hotels and hospitality, multifamily, offices, clinics, schools.
American homes are timber frame with gypsum board on both faces, so a party wall or a basement ceiling has almost no mass. Adding a second leaf with a limp membrane between does more than any amount of surface treatment.
- Wall array Panels placed at first reflection points rather than spread evenly. Fewer panels, better result.
- Ceiling first In most rooms the ceiling is the largest untreated surface and the cheapest square metre of result.
- Mixed finish Plain felt where it is out of eye line, printed or grooved where it is seen.
- What it will not do Coverage is not the target, reverberation time is. Lining every surface wastes money and can leave a room sounding dead and unpleasant.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for our acoustic panel range are on the main product page. This page covers what that means for a project in Florida.
PET felt acoustic panels Printed acoustic felt panels Grooved PET panels
02 / Specification sheet
The numbers, and they do not move by city
Nothing below changes by location. The decisions that do change are grade, thickness and how the material is mounted, and those are covered further down.
- EchoCore 151500 GSM. General commercial
- EchoPro 181800 GSM. Rooms with a written RT target
- EchoMax 222200 GSM. High occupancy and high level spaces
| Plain PET felt | 9 to 24 mm, 1220 x 2440 mm standard, up to 2440 x 4270 mm, 1200 to 3600 GSM |
|---|---|
| Printed felt | 1800 x 900 mm, image printed into the felt rather than onto a facing |
| Grooved panels | Cut pattern in PET felt, adds visual rhythm without changing the absorber |
| Test standard | ASTM C423 |
Where a consultant is already engaged on a Florida project, we supply to their specification and send the test reports rather than describing them. More on working with acoustic consultants.
03 / On the ground
What we see driving Florida briefs
- Heat and humidity all year
PET felt does not absorb moisture, shed fibre or feed mould, which matters where mineral products sag and hold damp.
- Block and concrete construction
Storm-rated building means real mass in the walls. Airborne transfer is rarely the issue. Impact through slabs and live interiors are.
- Impact through hard floors
Tile over a concrete slab passes footfall straight down between units. A resilient underlay before the finish is the fix.
- Ports in the state
Containers land in Florida itself, so there is no cross-country leg and the landed cost stays predictable.
- School and campus buildings
Public school buildings run long corridors with hard floors and lay-in tile ceilings that were chosen for cost, not for speech. Classroom reverberation and corridor spill are the two complaints, and both respond to ceiling area rather than wall panels.
- The studio and content scene
Home and project studios go into basements and converted garages with equipment budgets far ahead of the building. The room leaks to the floor above long before it sounds wrong inside.
Architects working in Florida usually need the build-up before the product. We will draw the section and mark what does the work. See how we support architects.
04 / Climate and durability
The Florida climate decides the material list
Florida is hot dry summers and mild wet winters, and that narrows the sensible material list before acoustics is even discussed.
The swing between a dry summer and a wet winter moves timber. PET felt is dimensionally stable across that swing; slat panels want a stable substrate and a ventilated fixing.
The risk we design against here is seasonal movement in timber and winter damp in unheated stock.
Interior designers tend to arrive with the look already decided. We will tell you which finish gets there without losing the acoustics. See how we work with interior designers.
05 / Route to site
What the route into Florida actually looks like
| Ships from | Palwal, Haryana, India |
|---|---|
| Arrives at | Jacksonville, Miami or Port Everglades, then road to site |
| Dispatch | 4 to 7 working days |
| Freight | Sea via Jacksonville or Miami |
| Packing | Palletised flat and film wrapped. Printed panels interleaved and corner protected. |
| Lead time | 4 to 7 working days standard. Printed and grooved take longer. |
Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.
Sea freight into Jacksonville, Miami or Port Everglades, then road to site. Air freight for samples and urgent quantities.
200 panels for a trial order, in any mix of thickness, GSM and colour. Beyond a trial we would rather quote a container load.
| Trial order | 200 panels, 6,400 sq ft, mixed thickness, GSM and colour |
|---|---|
| Recommended | Full container |
A panel is 1220 x 2440 mm, which is 32 sq ft.
06 / Before you buy
Four honest warnings before you buy
-
The wrong product for the problem
Coverage is not the target, reverberation time is. Lining every surface wastes money and can leave a room sounding dead and unpleasant. We would rather calculate the area than sell the wall.
-
Square footage quoted before the room is understood
Anyone can price a wall. Working out how much material the room actually needs usually reduces the order, which is why not everyone does it.
-
Local approvals that nobody actually holds
We hold no Florida certification and we will not borrow one. The test data we publish is ours, and we will send the reports rather than describe them.
07 / In projects
In finished rooms
Florida: questions we are actually asked
Are these acoustic panels made in Florida?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Florida as the manufacturer rather than through a dealer. Made at our own plant in India and shipped into Jacksonville, Miami or Port Everglades, so the container lands in the state rather than crossing the country. You buy at factory prices with one consistent batch across the order.
What do you look at first on a Florida enquiry?
Storm-rated building means real mass in the walls. Airborne transfer is rarely the issue. Impact through slabs and live interiors are. Tile over a concrete slab passes footfall straight down between units. A resilient underlay before the finish is the fix. Those two things move the build-up far more than the panel figure does.
How does the Florida climate affect this product?
Florida is hot dry summers and mild wet winters. The swing between a dry summer and a wet winter moves timber. PET felt is dimensionally stable across that swing; slat panels want a stable substrate and a ventilated fixing. The failure we design against here is seasonal movement in timber and winter damp in unheated stock.
How quickly can material reach a site in Florida?
ships from: Palwal, Haryana, India, arrives at: Jacksonville, Miami or Port Everglades, then road to site, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.
Where do acoustic panels fail to help?
Coverage is not the target, reverberation time is. Lining every surface wastes money and can leave a room sounding dead and unpleasant. We would rather calculate the area than sell the wall.
What is the minimum order and how is it packed?
200 panels for a trial order, in any mix of thickness, GSM and colour. Beyond a trial we would rather quote a container load. Trial order, 200 panels, 6,400 sq ft, mixed thickness, GSM and colour. Recommended, Full container. A panel is 1220 x 2440 mm, which is 32 sq ft. Palletised flat and film wrapped. Printed panels interleaved and corner protected.
Next step
Send the drawings, get a straight answer
We quote from drawings, not from a square foot rate. Send a plan and the section through the critical wall or ceiling and you will get something you can actually build from.