Home > Czechia > Wooden slat acoustic panels

Acoustic wooden slat wall and ceiling in a premium auditorium

Manufactured in India, supplied in Czechia

Wooden slat acoustic panels in Czechia

We manufacture wooden slat acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Czechia. Made at our own plant in India and shipped into Hamburg, then rail and road inland, with container pricing that suits the way Czech projects buy.

Substrate
MDF, FR MDF, HDF or HDHMR
Patterns
13-3, 14-2, 28-4 and 59-5
Panel sizes
2440 x 192 mm and 2440 x 128 mm
Thickness
14, 16 and 18 mm
Coverage
96 sq ft per unit
Lead time
Longer than felt
Minimum order
500 sq ft, about 46 sq m
  • EN 13501-1 Class B s1 d0 on FR substrate
  • Made at our own plant, Palwal, Haryana, India
  • One batch across the order, no blending between runs

We are the manufacturer. There is no local office and we do not claim approvals we do not hold. What you get is factory pricing, one consistent batch across the order, and a straight answer on what the material will and will not do.

01 / The material

What you are buying, and what it fixes in Czechia

Timber slats on an acoustic backing. The slats are the finish and the rhythm, the backing does the absorbing. Used where the room has to look considered rather than treated.

Work reaching us from Czechia is mostly production halls, plant rooms, offices, panel block apartments, schools, clinics.

Panel block housing has concrete walls with good mass but no impact isolation, while older masonry stock has timber floors that pass footfall.

  • Slats on felt backing The standard. Absorption comes from the backing behind the gaps, so the slat gap ratio is an acoustic decision, not only a visual one.
  • Slats on a cavity Backing plus an air gap behind moves absorption lower, which matters in music rooms.
  • Feature wall only Slats where they are seen, plain felt elsewhere, to hold the budget where it shows.
  • What it will not do A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

Full specification

Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for wooden slat panels are on the main product page. This page covers what that means for a project in Czechia.

Wooden slat acoustic panels SoundaXe wooden panels

02 / Data sheet

One specification sheet, the same in every market

Nothing below changes by location. The decisions that do change are grade, thickness and how the material is mounted, and those are covered further down.

  • MDFStandard. Dry interiors, general commercial
  • FR MDFFire rated. Public buildings and anywhere the specification calls for a class
  • HDHMRMoisture resistant. Humid climates and rooms that see damp
Wooden slat acoustic panels: published specification
SubstrateMDF, FR MDF, HDF or HDHMR
Patterns13-3, 14-2, 28-4 and 59-5
Panel sizes2440 x 192 mm and 2440 x 128 mm
Thickness14, 16 and 18 mm
Coverage96 sq ft per unit
Fire classEN 13501-1 Class B s1 d0 on FR substrate

If a consultant has set the target, we will quote against their figures rather than ours, and stay out of the scope they own. More on working with acoustic consultants.

03 / Local conditions

What the buildings in Czechia do to the specification

  • Panel block apartments

    Prefabricated concrete panel housing passes speech and footfall between flats through thin, well connected elements. Surface treatment does nothing here. Mass and a resilient break do.

  • Industrial noise is a mass problem

    Compressors, presses and extraction plant are low frequency and structure-borne. We will tell you when absorption is the wrong purchase rather than sell it to you.

  • Value is checked properly

    Czech buyers compare specifications line by line. That suits a manufacturer, because we can answer for what is actually in the product.

  • Landlocked, so plan the inland leg

    Hamburg then rail and road. We quote the sea leg and the inland leg separately so the programme is built on real dates.

  • Assembly and performance rooms

    Concert halls, church buildings and civic rooms are long-decay volumes in stone and plaster.

We would rather argue about the build-up at design stage than on site. See how we support architects.

04 / Climate and durability

Why the climate in Czechia changes the material, not the target

Czechia is cool and damp, with long heating seasons and cold external walls, and that narrows the sensible material list before acoustics is even discussed.

Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would.

The risk we design against here is condensation behind linings in older, poorly insulated stock.

Interior designers tend to arrive with the look already decided. We will tell you which finish gets there without losing the acoustics. See how we work with interior designers.

05 / Route to site

Getting it to Czechia, with real dates

Supply into Czechia
Ships fromPalwal, Haryana, India
Arrives atHamburg, then rail and road inland
Dispatch4 to 7 working days
FreightSea via Hamburg
PackingBraced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.
Lead timeLonger than felt. Confirmed against the pattern and substrate at quote stage.

Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.

Sea freight into Hamburg, then rail and road inland. Air freight for samples and urgent quantities.

The same 500 sq ft minimum applies on export.

Minimum order, wooden slat acoustic panels
Any specification500 sq ft, about 46 sq m

One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order.

06 / Read this first

Where this goes wrong, said plainly

  • The wrong product for the problem

    A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

  • Coverage bought instead of a target

    Lining every surface is a purchase, not a result. We would rather calculate the area against a reverberation target and sell you less of it.

  • A claim of being local to Czechia

    We manufacture in India and supply here. We do not run an office in this city and we will not pretend to, because you would find out on the first site visit.

FAQ

Czechia: questions we are actually asked

Is there a Czechia factory behind this product?

No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Czechia as the manufacturer rather than through a dealer. Made at our own plant in India and shipped into Hamburg, then rail and road inland, with container pricing that suits the way Czech projects buy. You buy at factory prices with one consistent batch across the order.

What do you look at first on a Czechia enquiry?

Prefabricated concrete panel housing passes speech and footfall between flats through thin, well connected elements. Surface treatment does nothing here. Mass and a resilient break do. Compressors, presses and extraction plant are low frequency and structure-borne. We will tell you when absorption is the wrong purchase rather than sell it to you. Those two things move the build-up far more than the panel figure does.

Is this the right material for Czechia conditions?

Czechia is cool and damp, with long heating seasons and cold external walls. Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would. The failure we design against here is condensation behind linings in older, poorly insulated stock.

When would material land on a Czechia site?

ships from: Palwal, Haryana, India, arrives at: Hamburg, then rail and road inland, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.

What should you not buy wooden slat acoustic panels for?

A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

What is the minimum order and how is it packed?

The same 500 sq ft minimum applies on export. Any specification, 500 sq ft, about 46 sq m. One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order. Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.

Next step

Drawings in, BOQ and a delivered date out

Send what you have. We will give you a layer by layer build-up, a bill of quantities and a date material lands, and we will flag anything in the brief that will not achieve what you want.