Home > Auckland > Soundproofing materials

Soundproofing Material & Noise Isolation Supplier in Abu Dhabi

Manufactured in India, supplied in Auckland

Soundproofing materials in Auckland

We manufacture soundproofing materials at our own plant at Palwal in Haryana, India, and supply them into Auckland. Made at our own plant in India and shipped straight into Auckland, so the container arrives at the city rather than a long domestic leg away.

SoundBlanket MLV
2100 kg per cubic metre. 2.5 mm STC 30 at 5.25 kg per sq m, 4 mm STC 34 at 8.4, 6 mm at 12.6
BassBloc
1800 x 900 x 20 mm, 100 kg per cubic metre, NRC 0.85
Principle
Mass, then decoupling, then cavity absorption, then sealing
Test standards
ASTM E90 for the barrier, ASTM C423 for the absorber
Lead time
4 to 7 working days for stock items
  • ASTM E90 for the barrier, ASTM C423 for the absorber
  • Made at our own plant, Palwal, Haryana, India
  • One batch across the order, no blending between runs

Manufacturer, not reseller. We hold no local approvals and will not imply we do. You get the price the factory quotes, material that matches across a large order, and advice that sometimes talks you out of a purchase.

01 / What it is

The material, and what it actually does on a Auckland job

The blocking side of the range taken together: mass loaded vinyl, resilient layers, cavity absorption and the build-ups they belong in. This is the page for someone whose problem is noise getting through, not a room that sounds wrong.

Work reaching us from Auckland is mostly apartments and townhouses, offices, hospitality, schools, clinics, studios.

Timber frame with plasterboard linings, so walls have very little mass. Apartment and townhouse party walls need a second leaf rather than surface treatment.

  • Independent leaf A second wall that does not touch the first. Nothing else comes close for the money.
  • Resilient bar Where a full independent leaf will not fit. Effective, and very easy to short circuit with one wrong screw.
  • Floating floor Resilient layer and deck, to break impact energy before it reaches the structure.
  • What it will not do Soundproofing fails at the gaps, not the materials. A service penetration, a back to back socket, or a door undercut will undo a correctly built wall.

Full specification

Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for our soundproofing materials are on the main product page. This page covers what that means for a project in Auckland.

SoundBlanket mass loaded vinyl BassBloc sound absorber Wall soundproofing systems

02 / Data sheet

Published specification, identical wherever we ship it

We publish one data sheet for every market. If a supplier quotes you a different figure for the same product in a different city, one of the two numbers is wrong.

  • Light retrofit2.5 mm membrane. Where depth is not available
  • Standard partition4 mm membrane on an independent leaf. The common specification
  • Heavy6 mm membrane and full decoupling. Plant, machine enclosure, low frequency
Soundproofing materials: published specification
SoundBlanket MLV2100 kg per cubic metre. 2.5 mm STC 30 at 5.25 kg per sq m, 4 mm STC 34 at 8.4, 6 mm at 12.6
BassBloc1800 x 900 x 20 mm, 100 kg per cubic metre, NRC 0.85
PrincipleMass, then decoupling, then cavity absorption, then sealing
Test standardsASTM E90 for the barrier, ASTM C423 for the absorber

If a consultant has set the target, we will quote against their figures rather than ours, and stay out of the scope they own. More on working with acoustic consultants.

03 / On the ground

The Auckland conditions that change the answer

  • Apartments built light and fast

    Townhouse and apartment stock built quickly in timber frame. The separating construction is where noise complaints concentrate.

  • Weathertightness shapes the build-up

    Wall assemblies here are designed around drainage and drying. An acoustic layer has to work with that, not trap moisture in it.

  • Volcanic ground, seismic detailing

    Flexible junctions are required, so a rigid acoustic bridge across a movement joint is not acceptable.

  • The port is in the city

    Direct sea into Auckland keeps the road leg short, though the sea leg itself is long and we quote it fully.

  • Plant and HVAC

    Heat pumps and ducted systems, with outdoor units close to boundaries in dense suburbs.

  • The housing stock

    Timber frame with plasterboard linings, so walls have very little mass. Apartment and townhouse party walls need a second leaf rather than surface treatment.

If you are specifying for a Auckland project, we can give you a section, a BOQ and the honest limits of each layer. See how we support architects.

04 / Climate and durability

What the Auckland climate rules in and rules out

Auckland is cool and damp, with long heating seasons and cold external walls, and that narrows the sensible material list before acoustics is even discussed.

Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would.

The risk we design against here is condensation behind linings in older, poorly insulated stock.

Designers get colour, pattern and CNC options with the absorption figure attached to each. See how we work with interior designers.

05 / Route to site

How material reaches a Auckland site

Supply into Auckland
Ships fromPalwal, Haryana, India
Arrives atAuckland, then a short road run to site
Dispatch4 to 7 working days
FreightSea into Auckland
PackingRolls on core tubes, boards palletised, fixings and tapes listed on the same packing list.
Lead time4 to 7 working days for stock items.

Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.

Sea freight direct into Auckland, then a short road run to site. Air freight for samples and urgent quantities.

06 / Read this first

Four honest warnings before you buy

  • The wrong product for the problem

    Soundproofing fails at the gaps, not the materials. A service penetration, a back to back socket, or a door undercut will undo a correctly built wall. We would rather spend the conversation on the detail than on the product.

  • A number chased without a measurement

    If nobody has measured the room or set a target, the specification is a guess with a decimal point in it. We will ask for the target before we quote the quantity.

  • Local approvals that nobody actually holds

    We hold no Auckland certification and we will not borrow one. The test data we publish is ours, and we will send the reports rather than describe them.

07 / In projects

How it looks once it is installed

Acoustic curtains
Acoustic curtains
Acoustic fabric panels
Acoustic fabric panels
Custom soundproofing systems
Custom soundproofing systems
Acoustic wall panels in an airport lounge, soundproofing materials in Abu Dhabi
Acoustic wall panels in an airport lounge, soundproofing materials in Abu Dhabi
Auditorium with wooden acoustic wall and ceiling treatment
Auditorium with wooden acoustic wall and ceiling treatment
Cinema hall with fabric acoustic wall panels
Cinema hall with fabric acoustic wall panels
FAQ

Auckland: questions we are actually asked

Do you manufacture soundproofing materials in Auckland?

No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Auckland as the manufacturer rather than through a dealer. Made at our own plant in India and shipped straight into Auckland, so the container arrives at the city rather than a long domestic leg away. You buy at factory prices with one consistent batch across the order.

What decides the specification for a Auckland project?

Townhouse and apartment stock built quickly in timber frame. The separating construction is where noise complaints concentrate. Wall assemblies here are designed around drainage and drying. An acoustic layer has to work with that, not trap moisture in it. Those two things move the build-up far more than the panel figure does.

Does Auckland weather shorten the life of this material?

Auckland is cool and damp, with long heating seasons and cold external walls. Cold wall build-ups and long heating seasons mean interstitial condensation is a real risk behind any lining. PET felt is unaffected by damp air and will not feed mould where a fabric-faced mineral product would. The failure we design against here is condensation behind linings in older, poorly insulated stock.

How quickly can material reach a site in Auckland?

ships from: Palwal, Haryana, India, arrives at: Auckland, then a short road run to site, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.

What should you not buy soundproofing materials for?

Soundproofing fails at the gaps, not the materials. A service penetration, a back to back socket, or a door undercut will undo a correctly built wall. We would rather spend the conversation on the detail than on the product.

How is the order packed and what is the minimum?

Minimum order is confirmed with the quote. Rolls on core tubes, boards palletised, fixings and tapes listed on the same packing list.

Next step

Send the drawings, get a straight answer

A plan and a section is enough. We will come back with a build-up, a BOQ and a delivered date, and we will say so if what you are asking for will not work.