Manufactured in India, supplied in Athens
SoundBlanket mass loaded vinyl in Athens
We manufacture soundBlanket mass loaded vinyl at our own plant at Palwal in Haryana, India, and supply them into Athens. Made at our own plant in India and shipped into Piraeus, beside the city, so the road leg to site is short.
- Density
- 2100 kg per cubic metre
- 2.5 mm
- STC 30, 5.25 kg per sq m
- 4 mm
- STC 34, 8.4 kg per sq m
- 6 mm
- 12.6 kg per sq m, STC on request
- Roll size
- 5 x 1.2 m, 6 sq m per roll
- Lead time
- 4 to 7 working days
- Minimum order
- From 10 rolls
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
- Test reports sent on request, not just quoted
This comes from our own plant, not a trading desk. We do not have an office in your city and we will not invent one. What we can give you is factory pricing, consistent material and a technical answer before you commit.
01 / What it is
The product, described honestly, for a Athens brief
A limp, high density sheet that adds mass to a partition, floor or duct without adding depth. It is the barrier product, not an absorber, and it is the right answer when the problem is noise passing through a structure.
Work reaching us from Athens is mostly apartment blocks, hotels and short lets, restaurants and roof terraces, offices, clinics, schools.
Concrete frame polykatoikia blocks with marble and tile floors throughout, sharing slabs and light wells.
- Wall, decoupled Independent stud, membrane between the boards, cavity absorption, two boards. The membrane is one part of a system, never the whole answer.
- Floor, floating Membrane under a resilient layer and a floating deck, so impact energy is broken before it reaches the slab.
- Duct and plant wrap Membrane wrapped over the duct with a decoupling layer beneath, sealed at every lap.
- What it will not do Mass fixed hard to an existing wall gives far less than the same mass on an independent leaf. If we are told the wall cannot be thickened, we will say what the membrane will and will not achieve rather than quote the laboratory figure and let the site find out.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for SoundBlanket MLV are on the main product page. This page covers what that means for a project in Athens.
02 / Data sheet
Published specification, identical wherever we ship it
We publish one data sheet for every market. If a supplier quotes you a different figure for the same product in a different city, one of the two numbers is wrong.
- 2.5 mmSTC 30, 5.25 kg per sq m. Ducts, light partitions, retrofit where depth is tight
- 4 mmSTC 34, 8.4 kg per sq m. Party walls, floors, plant rooms, the common specification
- 6 mm12.6 kg per sq m. Machine enclosures and low frequency problems
| Density | 2100 kg per cubic metre |
|---|---|
| 2.5 mm | STC 30, 5.25 kg per sq m |
| 4 mm | STC 34, 8.4 kg per sq m |
| 6 mm | 12.6 kg per sq m, STC on request |
| Roll size | 5 x 1.2 m, 6 sq m per roll |
| Form | Limp sheet, cuts with a knife, seams lapped and sealed |
Consultants get the raw data, not a sales sheet. That is the whole of our side of the job, and it is set out under working with acoustic consultants.
03 / On the ground
What the buildings in Athens do to the specification
- Concrete blocks, hard interiors
The structure carries mass, so airborne transfer between flats is rarely the issue. Marble and tile making the room ring is.
- Impact through slabs
Hard flooring over concrete passes footfall straight down. A resilient underlay before the finish is the fix, not a treatment below.
- Roof terraces and late trading
Venues operate above and beside homes through a long season, so containment is what protects the operation.
- Piraeus is next to the city
Direct sea into the port beside Athens keeps landed cost and dates both predictable.
- The housing stock
Concrete frame polykatoikia blocks with marble and tile floors throughout, sharing slabs and light wells.
- The studio and content scene
A music and content sector working inside apartment blocks where the neighbour sets the limit.
If you are specifying for a Athens project, we can give you a section, a BOQ and the honest limits of each layer. See how we support architects.
04 / Conditions
Why the climate in Athens changes the material, not the target
Athens is hot dry summers and mild wet winters, and that narrows the sensible material list before acoustics is even discussed.
The swing between a dry summer and a wet winter moves timber. PET felt is dimensionally stable across that swing; slat panels want a stable substrate and a ventilated fixing.
The risk we design against here is seasonal movement in timber and winter damp in unheated stock.
If the visual is fixed and the room still has to perform, that is a solvable problem and a conversation worth having early. See how we work with interior designers.
05 / Route to site
Supply into Athens, start to site
| Ships from | Palwal, Haryana, India |
|---|---|
| Arrives at | Piraeus, then a short road run to site |
| Dispatch | 4 to 7 working days |
| Freight | Sea via Piraeus |
| Packing | Rolls on core tubes, wrapped and end capped, 5 x 1.2 m. Weights on the packing list, because a full roll is heavy and site access matters. |
| Lead time | 4 to 7 working days. Full container quantities scheduled against the vessel. |
Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.
Sea freight into Piraeus, then a short road run to site. Air freight for samples and urgent quantities.
The same minimums apply on export as on domestic orders.
| 2.5 mm and 4 mm | 10 rolls, 60 sq m |
|---|---|
| 6 mm and other thicknesses | 10 tonnes per thickness |
A SoundBlanket roll is 5 x 1.2 m, which is 6 sq m. At 2100 kg per cubic metre a roll weighs about 31.5 kg at 2.5 mm and about 50.4 kg at 4 mm, so a 10 roll minimum is 60 sq m and roughly 315 kg at 2.5 mm or 504 kg at 4 mm.
06 / Worth knowing
Four honest warnings before you buy
-
The wrong product for the problem
Mass fixed hard to an existing wall gives far less than the same mass on an independent leaf. If we are told the wall cannot be thickened, we will say what the membrane will and will not achieve rather than quote the laboratory figure and let the site find out.
-
Coverage bought instead of a target
Lining every surface is a purchase, not a result. We would rather calculate the area against a reverberation target and sell you less of it.
-
A claim of being local to Athens
We manufacture in India and supply here. We do not run an office in this city and we will not pretend to, because you would find out on the first site visit.
Athens: questions we are actually asked
Is there a Athens factory behind this product?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Athens as the manufacturer rather than through a dealer. Made at our own plant in India and shipped into Piraeus, beside the city, so the road leg to site is short. You buy at factory prices with one consistent batch across the order.
What changes the specification on a Athens job?
The structure carries mass, so airborne transfer between flats is rarely the issue. Marble and tile making the room ring is. Hard flooring over concrete passes footfall straight down. A resilient underlay before the finish is the fix, not a treatment below. Those two things move the build-up far more than the panel figure does.
Is this the right material for Athens conditions?
Athens is hot dry summers and mild wet winters. The swing between a dry summer and a wet winter moves timber. PET felt is dimensionally stable across that swing; slat panels want a stable substrate and a ventilated fixing. The failure we design against here is seasonal movement in timber and winter damp in unheated stock.
How quickly can material reach a site in Athens?
ships from: Palwal, Haryana, India, arrives at: Piraeus, then a short road run to site, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.
When are soundBlanket mass loaded vinyl the wrong purchase?
Mass fixed hard to an existing wall gives far less than the same mass on an independent leaf. If we are told the wall cannot be thickened, we will say what the membrane will and will not achieve rather than quote the laboratory figure and let the site find out.
What quantity do we have to order, and in what packaging?
The same minimums apply on export as on domestic orders. 2.5 mm and 4 mm, 10 rolls, 60 sq m. 6 mm and other thicknesses, 10 tonnes per thickness. A SoundBlanket roll is 5 x 1.2 m, which is 6 sq m. At 2100 kg per cubic metre a roll weighs about 31.5 kg at 2.5 mm and about 50.4 kg at 4 mm, so a 10 roll minimum is 60 sq m and roughly 315 kg at 2.5 mm or 504 kg at 4 mm. Rolls on core tubes, wrapped and end capped, 5 x 1.2 m. Weights on the packing list, because a full roll is heavy and site access matters.
Next step
Drawings in, BOQ and a delivered date out
One drawing gets you a proper answer. Build-up, quantities, a delivered date, and an honest note on anything we think is the wrong approach.