Manufactured in India, supplied in Athens
Wooden slat acoustic panels in Athens
We manufacture wooden slat acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Athens. Made at our own plant in India and shipped into Piraeus, beside the city, so the road leg to site is short.
- Substrate
- MDF, FR MDF, HDF or HDHMR
- Patterns
- 13-3, 14-2, 28-4 and 59-5
- Panel sizes
- 2440 x 192 mm and 2440 x 128 mm
- Thickness
- 14, 16 and 18 mm
- Coverage
- 96 sq ft per unit
- Lead time
- Longer than felt
- Minimum order
- 500 sq ft, about 46 sq m
- EN 13501-1 Class B s1 d0 on FR substrate
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
We are the manufacturer. There is no local office and we do not claim approvals we do not hold. What you get is factory pricing, one consistent batch across the order, and a straight answer on what the material will and will not do.
01 / The material
What this is, and what it changes in a Athens room
Timber slats on an acoustic backing. The slats are the finish and the rhythm, the backing does the absorbing. Used where the room has to look considered rather than treated.
Work reaching us from Athens is mostly apartment blocks, hotels and short lets, restaurants and roof terraces, offices, clinics, schools.
Concrete frame polykatoikia blocks with marble and tile floors throughout, sharing slabs and light wells.
- Slats on felt backing The standard. Absorption comes from the backing behind the gaps, so the slat gap ratio is an acoustic decision, not only a visual one.
- Slats on a cavity Backing plus an air gap behind moves absorption lower, which matters in music rooms.
- Feature wall only Slats where they are seen, plain felt elsewhere, to hold the budget where it shows.
- What it will not do A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for wooden slat panels are on the main product page. This page covers what that means for a project in Athens.
02 / Specification
The published figures, unchanged by location
Nothing below changes by location. The decisions that do change are grade, thickness and how the material is mounted, and those are covered further down.
- MDFStandard. Dry interiors, general commercial
- FR MDFFire rated. Public buildings and anywhere the specification calls for a class
- HDHMRMoisture resistant. Humid climates and rooms that see damp
| Substrate | MDF, FR MDF, HDF or HDHMR |
|---|---|
| Patterns | 13-3, 14-2, 28-4 and 59-5 |
| Panel sizes | 2440 x 192 mm and 2440 x 128 mm |
| Thickness | 14, 16 and 18 mm |
| Coverage | 96 sq ft per unit |
| Fire class | EN 13501-1 Class B s1 d0 on FR substrate |
On a Athens job with a consultant involved, our part is material that matches the submitted data. See working with acoustic consultants.
03 / On the ground
What decides the build-up in Athens
- Concrete blocks, hard interiors
The structure carries mass, so airborne transfer between flats is rarely the issue. Marble and tile making the room ring is.
- Impact through slabs
Hard flooring over concrete passes footfall straight down. A resilient underlay before the finish is the fix, not a treatment below.
- Roof terraces and late trading
Venues operate above and beside homes through a long season, so containment is what protects the operation.
- Piraeus is next to the city
Direct sea into the port beside Athens keeps landed cost and dates both predictable.
- Assembly and performance rooms
Church buildings, civic halls and open air venues are hard volumes with long decay.
Architects working in Athens usually need the build-up before the product. We will draw the section and mark what does the work. See how we support architects.
04 / Climate and durability
Why the climate in Athens changes the material, not the target
Athens is hot dry summers and mild wet winters, and that narrows the sensible material list before acoustics is even discussed.
The swing between a dry summer and a wet winter moves timber. PET felt is dimensionally stable across that swing; slat panels want a stable substrate and a ventilated fixing.
The risk we design against here is seasonal movement in timber and winter damp in unheated stock.
Designers get colour, pattern and CNC options with the absorption figure attached to each. See how we work with interior designers.
05 / Supply
What the route into Athens actually looks like
| Ships from | Palwal, Haryana, India |
|---|---|
| Arrives at | Piraeus, then a short road run to site |
| Dispatch | 4 to 7 working days |
| Freight | Sea via Piraeus |
| Packing | Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry. |
| Lead time | Longer than felt. Confirmed against the pattern and substrate at quote stage. |
Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.
Sea freight into Piraeus, then a short road run to site. Air freight for samples and urgent quantities.
The same 500 sq ft minimum applies on export.
| Any specification | 500 sq ft, about 46 sq m |
|---|
One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order.
06 / Before you buy
Where this goes wrong, said plainly
-
The wrong product for the problem
A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
-
Coverage bought instead of a target
Lining every surface is a purchase, not a result. We would rather calculate the area against a reverberation target and sell you less of it.
-
Suppliers who imply a Athens presence
Ask any supplier where the material is made and who carries the warranty. We make it at Palwal in Haryana and we say so on every page, including this one.
Athens: questions we are actually asked
Do you manufacture wooden slat acoustic panels in Athens?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Athens as the manufacturer rather than through a dealer. Made at our own plant in India and shipped into Piraeus, beside the city, so the road leg to site is short. You buy at factory prices with one consistent batch across the order.
What do you look at first on a Athens enquiry?
The structure carries mass, so airborne transfer between flats is rarely the issue. Marble and tile making the room ring is. Hard flooring over concrete passes footfall straight down. A resilient underlay before the finish is the fix, not a treatment below. Those two things move the build-up far more than the panel figure does.
Is this the right material for Athens conditions?
Athens is hot dry summers and mild wet winters. The swing between a dry summer and a wet winter moves timber. PET felt is dimensionally stable across that swing; slat panels want a stable substrate and a ventilated fixing. The failure we design against here is seasonal movement in timber and winter damp in unheated stock.
What is the delivery time into Athens?
ships from: Palwal, Haryana, India, arrives at: Piraeus, then a short road run to site, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. Grooved panels and custom colours take longer, and we say so before you order, not after.
When are wooden slat acoustic panels the wrong purchase?
A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
What is the minimum order and how is it packed?
The same 500 sq ft minimum applies on export. Any specification, 500 sq ft, about 46 sq m. One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order. Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.
Next step
Drawings in, BOQ and a delivered date out
Send what you have. We will give you a layer by layer build-up, a bill of quantities and a date material lands, and we will flag anything in the brief that will not achieve what you want.