Home > Washington DC > PET felt acoustic panels
Manufactured in India, supplied in Washington DC
PET felt acoustic panels in Washington DC
We manufacture PET felt acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Washington DC. Made at our own plant in India and shipped into Baltimore or Norfolk, then a short road run into the city, with the full transit window quoted openly.
- Material
- 100% PET non-woven, no added binder
- Thickness
- 9, 12, 18 and 24 mm standard, tolerance plus or minus 5 percent
- Custom thickness
- 4 to 24 mm
- Panel size
- 1220 x 2440 mm standard, 4 x 8 ft
- Maximum size
- 2440 x 4270 mm, 2.44 x 4.27 m, 8 x 14 ft
- Lead time
- 4 to 7 working days for standard colours and thicknesses
- Minimum order
- From 10 panels
- ASTM C423
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
We are the manufacturer. There is no local office and we do not claim approvals we do not hold. What you get is factory pricing, one consistent batch across the order, and a straight answer on what the material will and will not do.
01 / Start here
What this material is and where it earns its place in Washington DC
A rigid non-woven panel pressed from 100% polyester fibre, a large part of it recycled. It absorbs mid and high frequency energy and finishes as the visible surface, so it is both the acoustic layer and the finish.
Work reaching us from Washington DC is mostly institutional and association offices, meeting and briefing rooms, hotels, schools, clinics.
American homes are timber frame with gypsum board on both faces, so a party wall or a basement ceiling has almost no mass. Adding a second leaf with a limp membrane between does more than any amount of surface treatment.
- Direct to wall Panel bonded or mechanically fixed flat to the substrate. Simplest, and the weakest at low frequency.
- On a 25 to 50 mm air gap The same panel on battens. The air gap moves absorption down in frequency at no extra material cost, and is the cheapest improvement available.
- Over a porous backing Panel over mineral or PET backing where the room needs genuine low mid control.
- What it will not do It absorbs. It does not block.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for PET felt panels are on the main product page. This page covers what that means for a project in Washington DC.
02 / Specification sheet
Published specification, identical wherever we ship it
The specification below is the same everywhere we supply, because a specification that changed by city would not be a specification. What changes is which grade and build-up is the right buy, and that is what the rest of this page is about.
- EchoCore 151500 GSM. Offices, classrooms, general commercial
- EchoPro 181800 GSM. Studios, auditoria, rooms with a written RT target
- EchoMax 222200 GSM. High occupancy and high level spaces
| Material | 100% PET non-woven, no added binder |
|---|---|
| Thickness | 9, 12, 18 and 24 mm standard, tolerance plus or minus 5 percent |
| Custom thickness | 4 to 24 mm |
| Panel size | 1220 x 2440 mm standard, 4 x 8 ft |
| Maximum size | 2440 x 4270 mm, 2.44 x 4.27 m, 8 x 14 ft |
| Density range | 1200 to 3600 GSM |
| NRC | 0.30 at 9 mm, rising with thickness and air gap |
| Test standard | ASTM C423 |
Consultants get the raw data, not a sales sheet. That is the whole of our side of the job, and it is set out under working with acoustic consultants.
03 / Local conditions
The Washington DC conditions that change the answer
- Privacy is the actual requirement
The question here is whether a conversation can be understood outside the room, not whether the room sounds pleasant. That needs the partition, the door and the ceiling handled together.
- Wide floorplates, low buildings
The height limit pushes buildings outward, so floors are broad and deep. Sound travels a long way across an open plan with nothing to interrupt it.
- Historic fabric downtown
Plenty of stock is old and protected. The work has to be internal and shallow, which rules out most thick framed systems.
- Meeting rooms used constantly
Association and institutional offices are mostly meeting space. Every one of those rooms has the same two demands: clear inside, inaudible outside.
- School and campus buildings
Public school buildings run long corridors with hard floors and lay-in tile ceilings that were chosen for cost, not for speech. Classroom reverberation and corridor spill are the two complaints, and both respond to ceiling area rather than wall panels.
If you are specifying for a Washington DC project, we can give you a section, a BOQ and the honest limits of each layer. See how we support architects.
04 / Durability
The Washington DC climate decides the material list
Washington DC is mild summers and cold, wet winters, and that narrows the sensible material list before acoustics is even discussed.
Cold external walls and long heating seasons make condensation behind a lining the thing to design out. PET felt is unaffected by damp air.
The risk we design against here is condensation and cold bridging behind new linings.
Designers get colour, pattern and CNC options with the absorption figure attached to each. See how we work with interior designers.
05 / Route to site
Getting it to Washington DC, with real dates
| Ships from | Palwal, Haryana, India |
|---|---|
| Arrives at | Baltimore or Norfolk, then road into the city |
| Dispatch | 4 to 7 working days |
| Freight | Sea via Baltimore or Norfolk |
| Packing | Palletised flat and film wrapped, cut sheets interleaved. Packing list and weights issued with the quote. |
| Lead time | 4 to 7 working days for standard colours and thicknesses. Grooved and custom colours take longer, and we say so before you order. |
Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.
Sea freight into Baltimore or Norfolk, then a short road run into the city. Air freight for samples and urgent quantities.
200 panels for a trial order, in any mix of thickness, GSM and colour. Beyond a trial we would rather quote a container load, because the price per panel and the freight per panel both fall sharply and a part load pays for space it does not use.
| Trial order | 200 panels, 6,400 sq ft, mixed thickness, GSM and colour |
|---|---|
| Recommended | Full container, for the best price per panel and the lowest freight per panel |
A panel is 1220 x 2440 mm, which is 32 sq ft.
06 / Before you buy
Where this goes wrong, said plainly
-
The wrong product for the problem
It absorbs. It does not block. A PET panel on a shared wall will make the room sound better and will not stop the neighbour being heard. If the brief is stopping noise passing through a wall or floor, the answer is mass and decoupling, and we will say so before quoting.
-
Square footage quoted before the room is understood
Anyone can price a wall. Working out how much material the room actually needs usually reduces the order, which is why not everyone does it.
-
A claim of being local to Washington DC
We manufacture in India and supply here. We do not run an office in this city and we will not pretend to, because you would find out on the first site visit.
Washington DC: questions we are actually asked
Is there a Washington DC factory behind this product?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Washington DC as the manufacturer rather than through a dealer. Made at our own plant in India and shipped into Baltimore or Norfolk, then a short road run into the city, with the full transit window quoted openly. You buy at factory prices with one consistent batch across the order.
What changes the specification on a Washington DC job?
The question here is whether a conversation can be understood outside the room, not whether the room sounds pleasant. That needs the partition, the door and the ceiling handled together. The height limit pushes buildings outward, so floors are broad and deep. Sound travels a long way across an open plan with nothing to interrupt it. Those two things move the build-up far more than the panel figure does.
How does the Washington DC climate affect this product?
Washington DC is mild summers and cold, wet winters. Cold external walls and long heating seasons make condensation behind a lining the thing to design out. PET felt is unaffected by damp air. The failure we design against here is condensation and cold bridging behind new linings.
How does an order actually travel to Washington DC?
ships from: Palwal, Haryana, India, arrives at: Baltimore or Norfolk, then road into the city, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.
What should you not buy PET felt acoustic panels for?
It absorbs. It does not block. A PET panel on a shared wall will make the room sound better and will not stop the neighbour being heard. If the brief is stopping noise passing through a wall or floor, the answer is mass and decoupling, and we will say so before quoting.
How is the order packed and what is the minimum?
200 panels for a trial order, in any mix of thickness, GSM and colour. Beyond a trial we would rather quote a container load, because the price per panel and the freight per panel both fall sharply and a part load pays for space it does not use. Trial order, 200 panels, 6,400 sq ft, mixed thickness, GSM and colour. Recommended, Full container, for the best price per panel and the lowest freight per panel. A panel is 1220 x 2440 mm, which is 32 sq ft. Palletised flat and film wrapped, cut sheets interleaved. Packing list and weights issued with the quote.
Next step
Send a plan and a section, get a real build-up
Send what you have. We will give you a layer by layer build-up, a bill of quantities and a date material lands, and we will flag anything in the brief that will not achieve what you want.