Home > Washington DC > PET felt acoustic panels

PET acoustic felt wall panels in office interior

Manufactured in India, supplied in Washington DC

PET felt acoustic panels in Washington DC

We manufacture PET felt acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Washington DC. Made at our own plant in India and shipped into Baltimore or Norfolk, then a short road run into the city, with the full transit window quoted openly.

Material
100% PET non-woven, no added binder
Thickness
9, 12, 18 and 24 mm standard, tolerance plus or minus 5 percent
Custom thickness
4 to 24 mm
Panel size
1220 x 2440 mm standard, 4 x 8 ft
Maximum size
2440 x 4270 mm, 2.44 x 4.27 m, 8 x 14 ft
Lead time
4 to 7 working days for standard colours and thicknesses
Minimum order
From 10 panels
  • ASTM C423
  • Made at our own plant, Palwal, Haryana, India
  • One batch across the order, no blending between runs

We are the manufacturer. There is no local office and we do not claim approvals we do not hold. What you get is factory pricing, one consistent batch across the order, and a straight answer on what the material will and will not do.

01 / Start here

What this material is and where it earns its place in Washington DC

A rigid non-woven panel pressed from 100% polyester fibre, a large part of it recycled. It absorbs mid and high frequency energy and finishes as the visible surface, so it is both the acoustic layer and the finish.

Work reaching us from Washington DC is mostly institutional and association offices, meeting and briefing rooms, hotels, schools, clinics.

American homes are timber frame with gypsum board on both faces, so a party wall or a basement ceiling has almost no mass. Adding a second leaf with a limp membrane between does more than any amount of surface treatment.

  • Direct to wall Panel bonded or mechanically fixed flat to the substrate. Simplest, and the weakest at low frequency.
  • On a 25 to 50 mm air gap The same panel on battens. The air gap moves absorption down in frequency at no extra material cost, and is the cheapest improvement available.
  • Over a porous backing Panel over mineral or PET backing where the room needs genuine low mid control.
  • What it will not do It absorbs. It does not block.

Full specification

Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for PET felt panels are on the main product page. This page covers what that means for a project in Washington DC.

PET felt acoustic panels

02 / Specification sheet

Published specification, identical wherever we ship it

The specification below is the same everywhere we supply, because a specification that changed by city would not be a specification. What changes is which grade and build-up is the right buy, and that is what the rest of this page is about.

  • EchoCore 151500 GSM. Offices, classrooms, general commercial
  • EchoPro 181800 GSM. Studios, auditoria, rooms with a written RT target
  • EchoMax 222200 GSM. High occupancy and high level spaces
PET felt acoustic panels: published specification
Material100% PET non-woven, no added binder
Thickness9, 12, 18 and 24 mm standard, tolerance plus or minus 5 percent
Custom thickness4 to 24 mm
Panel size1220 x 2440 mm standard, 4 x 8 ft
Maximum size2440 x 4270 mm, 2.44 x 4.27 m, 8 x 14 ft
Density range1200 to 3600 GSM
NRC0.30 at 9 mm, rising with thickness and air gap
Test standardASTM C423

Consultants get the raw data, not a sales sheet. That is the whole of our side of the job, and it is set out under working with acoustic consultants.

03 / Local conditions

The Washington DC conditions that change the answer

  • Privacy is the actual requirement

    The question here is whether a conversation can be understood outside the room, not whether the room sounds pleasant. That needs the partition, the door and the ceiling handled together.

  • Wide floorplates, low buildings

    The height limit pushes buildings outward, so floors are broad and deep. Sound travels a long way across an open plan with nothing to interrupt it.

  • Historic fabric downtown

    Plenty of stock is old and protected. The work has to be internal and shallow, which rules out most thick framed systems.

  • Meeting rooms used constantly

    Association and institutional offices are mostly meeting space. Every one of those rooms has the same two demands: clear inside, inaudible outside.

  • School and campus buildings

    Public school buildings run long corridors with hard floors and lay-in tile ceilings that were chosen for cost, not for speech. Classroom reverberation and corridor spill are the two complaints, and both respond to ceiling area rather than wall panels.

If you are specifying for a Washington DC project, we can give you a section, a BOQ and the honest limits of each layer. See how we support architects.

04 / Durability

The Washington DC climate decides the material list

Washington DC is mild summers and cold, wet winters, and that narrows the sensible material list before acoustics is even discussed.

Cold external walls and long heating seasons make condensation behind a lining the thing to design out. PET felt is unaffected by damp air.

The risk we design against here is condensation and cold bridging behind new linings.

Designers get colour, pattern and CNC options with the absorption figure attached to each. See how we work with interior designers.

05 / Route to site

Getting it to Washington DC, with real dates

Supply into Washington DC
Ships fromPalwal, Haryana, India
Arrives atBaltimore or Norfolk, then road into the city
Dispatch4 to 7 working days
FreightSea via Baltimore or Norfolk
PackingPalletised flat and film wrapped, cut sheets interleaved. Packing list and weights issued with the quote.
Lead time4 to 7 working days for standard colours and thicknesses. Grooved and custom colours take longer, and we say so before you order.

Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.

Sea freight into Baltimore or Norfolk, then a short road run into the city. Air freight for samples and urgent quantities.

200 panels for a trial order, in any mix of thickness, GSM and colour. Beyond a trial we would rather quote a container load, because the price per panel and the freight per panel both fall sharply and a part load pays for space it does not use.

Minimum order, pet felt acoustic panels
Trial order200 panels, 6,400 sq ft, mixed thickness, GSM and colour
RecommendedFull container, for the best price per panel and the lowest freight per panel

A panel is 1220 x 2440 mm, which is 32 sq ft.

06 / Before you buy

Where this goes wrong, said plainly

  • The wrong product for the problem

    It absorbs. It does not block. A PET panel on a shared wall will make the room sound better and will not stop the neighbour being heard. If the brief is stopping noise passing through a wall or floor, the answer is mass and decoupling, and we will say so before quoting.

  • Square footage quoted before the room is understood

    Anyone can price a wall. Working out how much material the room actually needs usually reduces the order, which is why not everyone does it.

  • A claim of being local to Washington DC

    We manufacture in India and supply here. We do not run an office in this city and we will not pretend to, because you would find out on the first site visit.

FAQ

Washington DC: questions we are actually asked

Is there a Washington DC factory behind this product?

No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Washington DC as the manufacturer rather than through a dealer. Made at our own plant in India and shipped into Baltimore or Norfolk, then a short road run into the city, with the full transit window quoted openly. You buy at factory prices with one consistent batch across the order.

What changes the specification on a Washington DC job?

The question here is whether a conversation can be understood outside the room, not whether the room sounds pleasant. That needs the partition, the door and the ceiling handled together. The height limit pushes buildings outward, so floors are broad and deep. Sound travels a long way across an open plan with nothing to interrupt it. Those two things move the build-up far more than the panel figure does.

How does the Washington DC climate affect this product?

Washington DC is mild summers and cold, wet winters. Cold external walls and long heating seasons make condensation behind a lining the thing to design out. PET felt is unaffected by damp air. The failure we design against here is condensation and cold bridging behind new linings.

How does an order actually travel to Washington DC?

ships from: Palwal, Haryana, India, arrives at: Baltimore or Norfolk, then road into the city, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.

What should you not buy PET felt acoustic panels for?

It absorbs. It does not block. A PET panel on a shared wall will make the room sound better and will not stop the neighbour being heard. If the brief is stopping noise passing through a wall or floor, the answer is mass and decoupling, and we will say so before quoting.

How is the order packed and what is the minimum?

200 panels for a trial order, in any mix of thickness, GSM and colour. Beyond a trial we would rather quote a container load, because the price per panel and the freight per panel both fall sharply and a part load pays for space it does not use. Trial order, 200 panels, 6,400 sq ft, mixed thickness, GSM and colour. Recommended, Full container, for the best price per panel and the lowest freight per panel. A panel is 1220 x 2440 mm, which is 32 sq ft. Palletised flat and film wrapped, cut sheets interleaved. Packing list and weights issued with the quote.

Next step

Send a plan and a section, get a real build-up

Send what you have. We will give you a layer by layer build-up, a bill of quantities and a date material lands, and we will flag anything in the brief that will not achieve what you want.