Home > Vapi > Wooden slat acoustic panels

Acoustic wooden slat wall and ceiling in a premium auditorium

Manufactured in India, supplied in Vapi

Wooden slat acoustic panels in Vapi

We manufacture wooden slat acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Vapi. Vapi is an industrial belt, and almost everything we supply here goes into a working plant rather than an interior.

Substrate
MDF, FR MDF, HDF or HDHMR
Patterns
13-3, 14-2, 28-4 and 59-5
Panel sizes
2440 x 192 mm and 2440 x 128 mm
Thickness
14, 16 and 18 mm
Coverage
96 sq ft per unit
Lead time
Longer than felt
Minimum order
500 sq ft, about 46 sq m
  • EN 13501-1 Class B s1 d0 on FR substrate
  • Made at our own plant, Palwal, Haryana, India
  • One batch across the order, no blending between runs

We make this ourselves and ship it to you. No local branch, no borrowed certifications, no dealer margin. One batch across the whole order, and an honest answer when the product is wrong for the problem.

01 / Start here

The product, described honestly, for a Vapi brief

Timber slats on an acoustic backing. The slats are the finish and the rhythm, the backing does the absorbing. Used where the room has to look considered rather than treated.

Work reaching us from Vapi is mostly process and chemical plants, utility and pump rooms, control rooms, offices, worker areas, clinics.

RC frame apartments and bungalows with stone and tile floors, in dry dusty conditions where open products collect dust.

  • Slats on felt backing The standard. Absorption comes from the backing behind the gaps, so the slat gap ratio is an acoustic decision, not only a visual one.
  • Slats on a cavity Backing plus an air gap behind moves absorption lower, which matters in music rooms.
  • Feature wall only Slats where they are seen, plain felt elsewhere, to hold the budget where it shows.
  • What it will not do A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

Full specification

Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for wooden slat panels are on the main product page. This page covers what that means for a project in Vapi.

Wooden slat acoustic panels SoundaXe wooden panels

02 / Data sheet

The numbers, and they do not move by city

We publish one data sheet for every market. If a supplier quotes you a different figure for the same product in a different city, one of the two numbers is wrong.

  • MDFStandard. Dry interiors, general commercial
  • FR MDFFire rated. Public buildings and anywhere the specification calls for a class
  • HDHMRMoisture resistant. Humid climates and rooms that see damp
Wooden slat acoustic panels: published specification
SubstrateMDF, FR MDF, HDF or HDHMR
Patterns13-3, 14-2, 28-4 and 59-5
Panel sizes2440 x 192 mm and 2440 x 128 mm
Thickness14, 16 and 18 mm
Coverage96 sq ft per unit
Fire classEN 13501-1 Class B s1 d0 on FR substrate

Consultants get the raw data, not a sales sheet. That is the whole of our side of the job, and it is set out under working with acoustic consultants.

03 / In this market

What decides the build-up in Vapi

  • Plant runs continuously

    Pumps, compressors and blowers do not stop, so the noise is constant rather than intermittent. Enclosure at the source is the only answer that holds.

  • Boundary noise matters

    Housing sits close to industry here. Containing sound inside the site is a separate design from making the control room usable.

  • Control rooms need a low floor

    Operators listening for alarms need background noise down before anything else matters.

  • Corrosive, humid air

    PET felt does not absorb moisture, rot or feed mould, which matters in a coastal industrial climate.

  • Assembly and performance rooms

    Auditoriums, banquet halls and places of worship are large hard volumes in concrete and stone where speech falls apart long before anyone calls the room echoey.

For a Vapi practice, the useful thing is a detail you can put in a drawing set, not a brochure. See how we support architects.

04 / Conditions

What the Vapi climate rules in and rules out

Vapi is hot and dry for most of the year, with dust and high daytime surface temperatures, and that narrows the sensible material list before acoustics is even discussed.

Dust is the enemy of open-cell products. PET felt does not shed, does not hold dust in the way fabric-wrapped glass wool does, and wipes down. Timber needs a stable indoor RH or it moves.

The risk we design against here is dust ingress and thermal movement in long runs.

If the visual is fixed and the room still has to perform, that is a solvable problem and a conversation worth having early. See how we work with interior designers.

05 / Route to site

Getting it to Vapi, with real dates

Supply into Vapi
Made atOur own plant, Palwal, Haryana
Reaches site inthree days
Dispatch2 to 4 working days
To sitethree days
PackingBraced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.
Lead timeLonger than felt. Confirmed against the pattern and substrate at quote stage.

Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.

By road from Palwal, roughly twelve hundred kilometres, normally three days on a dedicated truck.

500 sq ft, about 46 sq m, whatever the substrate, pattern, width or thickness.

Minimum order, wooden slat acoustic panels
Any specification500 sq ft, about 46 sq m

One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order.

06 / Before you buy

Where this goes wrong, said plainly

  • The wrong product for the problem

    A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

  • Coverage bought instead of a target

    Lining every surface is a purchase, not a result. We would rather calculate the area against a reverberation target and sell you less of it.

  • Local approvals that nobody actually holds

    We hold no Vapi certification and we will not borrow one. The test data we publish is ours, and we will send the reports rather than describe them.

FAQ

Vapi: questions we are actually asked

Where are the wooden slat acoustic panels you supply to Vapi actually made?

No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Vapi as the manufacturer rather than through a dealer. Vapi is an industrial belt, and almost everything we supply here goes into a working plant rather than an interior. You buy at factory prices with one consistent batch across the order.

What do you look at first on a Vapi enquiry?

Pumps, compressors and blowers do not stop, so the noise is constant rather than intermittent. Enclosure at the source is the only answer that holds. Housing sits close to industry here. Containing sound inside the site is a separate design from making the control room usable. Those two things move the build-up far more than the panel figure does.

How does the Vapi climate affect this product?

Vapi is hot and dry for most of the year, with dust and high daytime surface temperatures. Dust is the enemy of open-cell products. PET felt does not shed, does not hold dust in the way fabric-wrapped glass wool does, and wipes down. Timber needs a stable indoor RH or it moves. The failure we design against here is dust ingress and thermal movement in long runs.

How quickly can material reach a site in Vapi?

made at: Our own plant, Palwal, Haryana, reaches site in: three days, dispatch: 2 to 4 working days. Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.

Where do wooden slat acoustic panels fail to help?

A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

Is there a minimum order, and how does it arrive?

500 sq ft, about 46 sq m, whatever the substrate, pattern, width or thickness. Any specification, 500 sq ft, about 46 sq m. One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order. Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.

Next step

Send the drawings, get a straight answer

Send what you have. We will give you a layer by layer build-up, a bill of quantities and a date material lands, and we will flag anything in the brief that will not achieve what you want.