Home > Vadodara > Soundproofing materials

Soundproofing Material & Noise Isolation Supplier in Abu Dhabi

Manufactured in India, supplied in Vadodara

Soundproofing materials in Vadodara

We manufacture soundproofing materials at our own plant at Palwal in Haryana, India, and supply them into Vadodara. Vadodara is engineering and petrochemicals with a large education sector alongside, so plant rooms and lecture halls arrive in the same week.

SoundBlanket MLV
2100 kg per cubic metre. 2.5 mm STC 30 at 5.25 kg per sq m, 4 mm STC 34 at 8.4, 6 mm at 12.6
BassBloc
1800 x 900 x 20 mm, 100 kg per cubic metre, NRC 0.85
Principle
Mass, then decoupling, then cavity absorption, then sealing
Test standards
ASTM E90 for the barrier, ASTM C423 for the absorber
Lead time
4 to 7 working days for stock items
  • ASTM E90 for the barrier, ASTM C423 for the absorber
  • Made at our own plant, Palwal, Haryana, India
  • One batch across the order, no blending between runs

Manufacturer, not reseller. We hold no local approvals and will not imply we do. You get the price the factory quotes, material that matches across a large order, and advice that sometimes talks you out of a purchase.

01 / Start here

The product, described honestly, for a Vadodara brief

The blocking side of the range taken together: mass loaded vinyl, resilient layers, cavity absorption and the build-ups they belong in. This is the page for someone whose problem is noise getting through, not a room that sounds wrong.

Work reaching us from Vadodara is mostly engineering and process plant, colleges, hospitals, offices, auditoriums, hotels.

RC frame apartments and bungalows with stone and tile floors, in dry dusty conditions where open products collect dust.

  • Independent leaf A second wall that does not touch the first. Nothing else comes close for the money.
  • Resilient bar Where a full independent leaf will not fit. Effective, and very easy to short circuit with one wrong screw.
  • Floating floor Resilient layer and deck, to break impact energy before it reaches the structure.
  • What it will not do Soundproofing fails at the gaps, not the materials. A service penetration, a back to back socket, or a door undercut will undo a correctly built wall.

Full specification

Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for our soundproofing materials are on the main product page. This page covers what that means for a project in Vadodara.

SoundBlanket mass loaded vinyl BassBloc sound absorber Wall soundproofing systems

02 / Specification

The numbers, and they do not move by city

The specification below is the same everywhere we supply, because a specification that changed by city would not be a specification. What changes is which grade and build-up is the right buy, and that is what the rest of this page is about.

  • Light retrofit2.5 mm membrane. Where depth is not available
  • Standard partition4 mm membrane on an independent leaf. The common specification
  • Heavy6 mm membrane and full decoupling. Plant, machine enclosure, low frequency
Soundproofing materials: published specification
SoundBlanket MLV2100 kg per cubic metre. 2.5 mm STC 30 at 5.25 kg per sq m, 4 mm STC 34 at 8.4, 6 mm at 12.6
BassBloc1800 x 900 x 20 mm, 100 kg per cubic metre, NRC 0.85
PrincipleMass, then decoupling, then cavity absorption, then sealing
Test standardsASTM E90 for the barrier, ASTM C423 for the absorber

If a consultant has set the target, we will quote against their figures rather than ours, and stay out of the scope they own. More on working with acoustic consultants.

03 / What drives the brief

The Vadodara conditions that change the answer

  • Process and engineering plant

    Pumps, compressors and blowers running continuously close to occupied areas. Enclosure at the source is the answer.

  • Control rooms and labs

    Spaces that need a genuinely low background before measurement or monitoring means anything.

  • Teaching at scale

    Lecture halls in concrete and tile that defeat the speaker long before anyone calls the room echoey.

  • Dry heat

    PET felt does not sag, shed fibre or degrade at high temperature, which suits roof voids and sealed conditioned rooms.

  • Plant and HVAC

    Heavy industrial plant across the state, so compressors, presses and generator sets sit close to offices and canteens inside the same building.

  • The housing stock

    RC frame apartments and bungalows with stone and tile floors, in dry dusty conditions where open products collect dust.

If you are specifying for a Vadodara project, we can give you a section, a BOQ and the honest limits of each layer. See how we support architects.

04 / Climate and durability

Durability in Vadodara, before acoustics is discussed

Vadodara is hot and dry for most of the year, with dust and high daytime surface temperatures, and that narrows the sensible material list before acoustics is even discussed.

Dust is the enemy of open-cell products. PET felt does not shed, does not hold dust in the way fabric-wrapped glass wool does, and wipes down. Timber needs a stable indoor RH or it moves.

The risk we design against here is dust ingress and thermal movement in long runs.

Interior designers tend to arrive with the look already decided. We will tell you which finish gets there without losing the acoustics. See how we work with interior designers.

05 / Logistics

Getting it to Vadodara, with real dates

Supply into Vadodara
Made atOur own plant, Palwal, Haryana
Reaches site intwo days
Dispatch2 to 4 working days
To sitetwo days
PackingRolls on core tubes, boards palletised, fixings and tapes listed on the same packing list.
Lead time4 to 7 working days for stock items.

Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.

By road from Palwal, roughly nine hundred kilometres, normally two days on a dedicated truck.

06 / Worth knowing

What we will tell you that a reseller will not

  • The wrong product for the problem

    Soundproofing fails at the gaps, not the materials. A service penetration, a back to back socket, or a door undercut will undo a correctly built wall. We would rather spend the conversation on the detail than on the product.

  • A number chased without a measurement

    If nobody has measured the room or set a target, the specification is a guess with a decimal point in it. We will ask for the target before we quote the quantity.

  • A claim of being local to Vadodara

    We manufacture in India and supply here. We do not run an office in this city and we will not pretend to, because you would find out on the first site visit.

07 / In projects

How it looks once it is installed

Acoustic curtains
Acoustic curtains
Acoustic fabric panels
Acoustic fabric panels
Custom soundproofing systems
Custom soundproofing systems
Acoustic wall panels in an airport lounge, soundproofing materials in Abu Dhabi
Acoustic wall panels in an airport lounge, soundproofing materials in Abu Dhabi
Auditorium with wooden acoustic wall and ceiling treatment
Auditorium with wooden acoustic wall and ceiling treatment
Cinema hall with fabric acoustic wall panels
Cinema hall with fabric acoustic wall panels
FAQ

Vadodara: questions we are actually asked

Is there a Vadodara factory behind this product?

No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Vadodara as the manufacturer rather than through a dealer. Vadodara is engineering and petrochemicals with a large education sector alongside, so plant rooms and lecture halls arrive in the same week. You buy at factory prices with one consistent batch across the order.

What do you look at first on a Vadodara enquiry?

Pumps, compressors and blowers running continuously close to occupied areas. Enclosure at the source is the answer. Spaces that need a genuinely low background before measurement or monitoring means anything. Those two things move the build-up far more than the panel figure does.

How does the Vadodara climate affect this product?

Vadodara is hot and dry for most of the year, with dust and high daytime surface temperatures. Dust is the enemy of open-cell products. PET felt does not shed, does not hold dust in the way fabric-wrapped glass wool does, and wipes down. Timber needs a stable indoor RH or it moves. The failure we design against here is dust ingress and thermal movement in long runs.

What is the delivery time into Vadodara?

made at: Our own plant, Palwal, Haryana, reaches site in: two days, dispatch: 2 to 4 working days. Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.

What should you not buy soundproofing materials for?

Soundproofing fails at the gaps, not the materials. A service penetration, a back to back socket, or a door undercut will undo a correctly built wall. We would rather spend the conversation on the detail than on the product.

How is the order packed and what is the minimum?

Minimum order is confirmed with the quote. Rolls on core tubes, boards palletised, fixings and tapes listed on the same packing list.

Next step

Send the drawings, get a straight answer

A plan and a section is enough. We will come back with a build-up, a BOQ and a delivered date, and we will say so if what you are asking for will not work.