Manufactured in India, supplied in Sonipat
Wood wool acoustic panels in Sonipat
We manufacture wood wool acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Sonipat. Sonipat has become a university town alongside its industrial estates, which gives us campus work and plant work from the same district.
- Panel size
- 1200 x 600 mm
- Thickness
- 20 mm
- Density
- 400 kg per cubic metre
- NRC
- 0.30
- Test standards
- ASTM C-423 and EN ISO 354
- Lead time
- 4 to 7 working days for standard sizes
- Minimum order
- 500 sq ft, about 46 sq m
- ASTM C-423 and EN ISO 354
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
We make this ourselves and ship it to you. No local branch, no borrowed certifications, no dealer margin. One batch across the whole order, and an honest answer when the product is wrong for the problem.
01 / The product
What this material is and where it earns its place in Sonipat
Wood fibre bound into a rigid board with an open texture. Robust, paintable and used where the surface takes knocks, which is why it ends up in schools, sports halls and plant rooms.
Work reaching us from Sonipat is mostly university campuses, lecture halls and hostels, industrial units, offices, clinics, schools.
Builder floors and RC frame apartments with tile and stone floors, often built floor by floor for separate households.
- Direct fix Mechanically fixed to the soffit or wall. Durable and simple.
- On a cavity Mounted on battens with an air gap, which is where the low mid performance comes from.
- With a porous backing Board over mineral backing where the room needs more than the board alone gives.
- What it will not do At 20 mm it is a mid and high frequency absorber, not a bass solution, and painting it heavily will close the surface and reduce what it does. If a room needs low frequency control, depth or a cavity has to come from somewhere.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for wood wool panels are on the main product page. This page covers what that means for a project in Sonipat.
02 / Specification
Published specification, identical wherever we ship it
These figures are published and they do not move. The thing worth arguing about is not the number on the sheet, it is which grade and which build-up suits the room you are treating.
- Natural20 mm. Plant rooms, back of house, industrial
- Painted20 mm. Classrooms, halls, visible ceilings
| Panel size | 1200 x 600 mm |
|---|---|
| Thickness | 20 mm |
| Density | 400 kg per cubic metre |
| NRC | 0.30 |
| Test standards | ASTM C-423 and EN ISO 354 |
| Surface burning | Class A to ASTM E84 |
If a consultant has set the target, we will quote against their figures rather than ours, and stay out of the scope they own. More on working with acoustic consultants.
03 / On the ground
What we see driving Sonipat briefs
- Campus repetition
The same classroom or hostel detail across many blocks. Consistency across the order matters more than the figure on one sheet.
- Lecture halls defeat the speaker
Large teaching rooms in concrete and tile lose intelligibility long before anyone calls the room echoey.
- Industrial units nearby
Machinery close to occupied areas, where enclosure at the source is the reliable answer.
- An hour from the plant
Next day delivery, quick samples, and a site visit when the room is difficult.
- Assembly and performance rooms
Auditoriums, banquet halls and places of worship are large hard volumes in concrete and stone where speech falls apart long before anyone calls the room echoey.
- School and campus buildings
Classrooms are concrete and tile with bare walls and high ceilings, and class sizes push levels up. Corridors act as reverberation chambers that feed every room off them.
If you are specifying for a Sonipat project, we can give you a section, a BOQ and the honest limits of each layer. See how we support architects.
04 / Conditions
The Sonipat climate decides the material list
Sonipat is hot summers, mild winters and a distinct wet season, and that narrows the sensible material list before acoustics is even discussed.
PET felt handles the wet months without absorbing moisture or feeding mould. Timber and wood wool want a ventilated cavity and a stable indoor RH.
The risk we design against here is wet-season humidity behind linings.
If the visual is fixed and the room still has to perform, that is a solvable problem and a conversation worth having early. See how we work with interior designers.
05 / Supply
Getting it to Sonipat, with real dates
| Made at | Our own plant, Palwal, Haryana |
|---|---|
| Reaches site in | same or next day |
| Dispatch | 2 to 4 working days |
| To site | same or next day |
| Packing | Palletised flat, edge protected. Boards are rigid but the edges chip, so they travel protected. |
| Lead time | 4 to 7 working days for standard sizes. |
Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.
Same or next day by road from Palwal, about a hundred and twenty kilometres.
500 sq ft, about 46 sq m.
| Any finish | 500 sq ft, about 46 sq m |
|---|
A panel is 1200 x 600 mm, which is 0.72 sq m or about 7.75 sq ft, so the minimum is roughly 65 panels.
06 / Read this first
The things worth knowing before you place the order
-
The wrong product for the problem
At 20 mm it is a mid and high frequency absorber, not a bass solution, and painting it heavily will close the surface and reduce what it does. If a room needs low frequency control, depth or a cavity has to come from somewhere.
-
Coverage bought instead of a target
Lining every surface is a purchase, not a result. We would rather calculate the area against a reverberation target and sell you less of it.
-
A claim of being local to Sonipat
We manufacture in India and supply here. We do not run an office in this city and we will not pretend to, because you would find out on the first site visit.
Sonipat: questions we are actually asked
Where are the wood wool acoustic panels you supply to Sonipat actually made?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Sonipat as the manufacturer rather than through a dealer. Sonipat has become a university town alongside its industrial estates, which gives us campus work and plant work from the same district. You buy at factory prices with one consistent batch across the order.
What do you look at first on a Sonipat enquiry?
The same classroom or hostel detail across many blocks. Consistency across the order matters more than the figure on one sheet. Large teaching rooms in concrete and tile lose intelligibility long before anyone calls the room echoey. Those two things move the build-up far more than the panel figure does.
Does Sonipat weather shorten the life of this material?
Sonipat is hot summers, mild winters and a distinct wet season. PET felt handles the wet months without absorbing moisture or feeding mould. Timber and wood wool want a ventilated cavity and a stable indoor RH. The failure we design against here is wet-season humidity behind linings.
What is the delivery time into Sonipat?
made at: Our own plant, Palwal, Haryana, reaches site in: same or next day, dispatch: 2 to 4 working days. Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.
What should you not buy wood wool acoustic panels for?
At 20 mm it is a mid and high frequency absorber, not a bass solution, and painting it heavily will close the surface and reduce what it does. If a room needs low frequency control, depth or a cavity has to come from somewhere.
Is there a minimum order, and how does it arrive?
500 sq ft, about 46 sq m. Any finish, 500 sq ft, about 46 sq m. A panel is 1200 x 600 mm, which is 0.72 sq m or about 7.75 sq ft, so the minimum is roughly 65 panels. Palletised flat, edge protected. Boards are rigid but the edges chip, so they travel protected.
Next step
Tell us the room, we will tell you the build-up
We quote from drawings, not from a square foot rate. Send a plan and the section through the critical wall or ceiling and you will get something you can actually build from.