Manufactured in India, supplied in Rajkot
Acoustic panels in Rajkot
We manufacture acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Rajkot. Rajkot is castings and machine tools, which means foundries and machining halls where the noise is low frequency and structural.
- Plain PET felt
- 9 to 24 mm, 1220 x 2440 mm standard, up to 2440 x 4270 mm, 1200 to 3600 GSM
- Printed felt
- 1800 x 900 mm, image printed into the felt rather than onto a facing
- Grooved panels
- Cut pattern in PET felt, adds visual rhythm without changing the absorber
- Test standard
- ASTM C423
- Lead time
- 4 to 7 working days standard
- Minimum order
- From 10 panels
- ASTM C423
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
This comes from our own plant, not a trading desk. We do not have an office in your city and we will not invent one. What we can give you is factory pricing, consistent material and a technical answer before you commit.
01 / The product
What you are buying, and what it fixes in Rajkot
The full absorber range rather than one product: plain PET felt, printed felt, grooved panels and fabric finishes, chosen by how the room is used and how it has to look.
Work reaching us from Rajkot is mostly foundries and machining halls, engineering units, offices, colleges, hospitals, showrooms.
RC frame apartments and bungalows with stone and tile floors, in dry dusty conditions where open products collect dust.
- Wall array Panels placed at first reflection points rather than spread evenly. Fewer panels, better result.
- Ceiling first In most rooms the ceiling is the largest untreated surface and the cheapest square metre of result.
- Mixed finish Plain felt where it is out of eye line, printed or grooved where it is seen.
- What it will not do Coverage is not the target, reverberation time is. Lining every surface wastes money and can leave a room sounding dead and unpleasant.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for our acoustic panel range are on the main product page. This page covers what that means for a project in Rajkot.
PET felt acoustic panels Printed acoustic felt panels Grooved PET panels
02 / The numbers
Published specification, identical wherever we ship it
These figures are published and they do not move. The thing worth arguing about is not the number on the sheet, it is which grade and which build-up suits the room you are treating.
- EchoCore 151500 GSM. General commercial
- EchoPro 181800 GSM. Rooms with a written RT target
- EchoMax 222200 GSM. High occupancy and high level spaces
| Plain PET felt | 9 to 24 mm, 1220 x 2440 mm standard, up to 2440 x 4270 mm, 1200 to 3600 GSM |
|---|---|
| Printed felt | 1800 x 900 mm, image printed into the felt rather than onto a facing |
| Grooved panels | Cut pattern in PET felt, adds visual rhythm without changing the absorber |
| Test standard | ASTM C423 |
If a consultant has set the target, we will quote against their figures rather than ours, and stay out of the scope they own. More on working with acoustic consultants.
03 / Local conditions
What decides the build-up in Rajkot
- Heat inside the building
PET felt does not sag, shed fibre or degrade at high temperature, which matters in a foundry roof void.
- Foundry noise is structural
Furnaces, hammers and heavy machine tools put energy into the floor. Isolation and mass address that, and absorption does not.
- Machining halls
Continuous machine noise where instructions and alarms still have to be understood. Targeted absorption fixes intelligibility.
- Two to three days by road
A dedicated truck from Palwal, with samples sent ahead of the order.
- School and campus buildings
Large school and college campuses in concrete and tile, with assembly halls and auditoria in constant use.
- The studio and content scene
Studios go into basements, terrace rooms and back rooms with neighbours on every side and a generator somewhere in the lane. Isolating from the building has to come before treating the room.
We would rather argue about the build-up at design stage than on site. See how we support architects.
04 / Climate and durability
Why the climate in Rajkot changes the material, not the target
Rajkot is hot and dry for most of the year, with dust and high daytime surface temperatures, and that narrows the sensible material list before acoustics is even discussed.
Dust is the enemy of open-cell products. PET felt does not shed, does not hold dust in the way fabric-wrapped glass wool does, and wipes down. Timber needs a stable indoor RH or it moves.
The risk we design against here is dust ingress and thermal movement in long runs.
If the visual is fixed and the room still has to perform, that is a solvable problem and a conversation worth having early. See how we work with interior designers.
05 / Logistics
How material reaches a Rajkot site
| Made at | Our own plant, Palwal, Haryana |
|---|---|
| Reaches site in | two to three days |
| Dispatch | 2 to 4 working days |
| To site | two to three days |
| Packing | Palletised flat and film wrapped. Printed panels interleaved and corner protected. |
| Lead time | 4 to 7 working days standard. Printed and grooved take longer. |
Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.
By road from Palwal, roughly one thousand kilometres, normally two to three days on a dedicated truck.
From 10 panels for 9 mm EchoCore 15. Other grades and thicknesses carry their own minimum.
| 9 mm EchoCore 15, 1500 GSM | 10 panels, 320 sq ft |
|---|---|
| 9 mm EchoPro 18, 1800 GSM | 50 panels, 1,600 sq ft |
| 9 mm EchoMax 22, 2200 GSM | 100 panels, 3,200 sq ft |
| 12 mm, 2400 GSM | 30 panels, 960 sq ft |
| 18 mm, 3000 GSM | 50 panels, 1,600 sq ft |
| 24 mm, 3600 GSM | 50 panels, 1,600 sq ft |
A panel is 1220 x 2440 mm, which is 32 sq ft.
06 / Worth knowing
The things worth knowing before you place the order
-
The wrong product for the problem
Coverage is not the target, reverberation time is. Lining every surface wastes money and can leave a room sounding dead and unpleasant. We would rather calculate the area than sell the wall.
-
Coverage bought instead of a target
Lining every surface is a purchase, not a result. We would rather calculate the area against a reverberation target and sell you less of it.
-
Suppliers who imply a Rajkot presence
Ask any supplier where the material is made and who carries the warranty. We make it at Palwal in Haryana and we say so on every page, including this one.
07 / In projects
The material in real interiors
Rajkot: questions we are actually asked
Are these acoustic panels made in Rajkot?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Rajkot as the manufacturer rather than through a dealer. Rajkot is castings and machine tools, which means foundries and machining halls where the noise is low frequency and structural. You buy at factory prices with one consistent batch across the order.
Why would a Rajkot build-up differ from anywhere else?
Furnaces, hammers and heavy machine tools put energy into the floor. Isolation and mass address that, and absorption does not. Continuous machine noise where instructions and alarms still have to be understood. Targeted absorption fixes intelligibility. Those two things move the build-up far more than the panel figure does.
Will this material last in the Rajkot climate?
Rajkot is hot and dry for most of the year, with dust and high daytime surface temperatures. Dust is the enemy of open-cell products. PET felt does not shed, does not hold dust in the way fabric-wrapped glass wool does, and wipes down. Timber needs a stable indoor RH or it moves. The failure we design against here is dust ingress and thermal movement in long runs.
What is the delivery time into Rajkot?
made at: Our own plant, Palwal, Haryana, reaches site in: two to three days, dispatch: 2 to 4 working days. Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.
Where do acoustic panels fail to help?
Coverage is not the target, reverberation time is. Lining every surface wastes money and can leave a room sounding dead and unpleasant. We would rather calculate the area than sell the wall.
What quantity do we have to order, and in what packaging?
From 10 panels for 9 mm EchoCore 15. Other grades and thicknesses carry their own minimum. 9 mm EchoCore 15, 1500 GSM, 10 panels, 320 sq ft. 9 mm EchoPro 18, 1800 GSM, 50 panels, 1,600 sq ft. 9 mm EchoMax 22, 2200 GSM, 100 panels, 3,200 sq ft. 12 mm, 2400 GSM, 30 panels, 960 sq ft. 18 mm, 3000 GSM, 50 panels, 1,600 sq ft. 24 mm, 3600 GSM, 50 panels, 1,600 sq ft. A panel is 1220 x 2440 mm, which is 32 sq ft. Palletised flat and film wrapped. Printed panels interleaved and corner protected.
Next step
Send the drawings, get a straight answer
One drawing gets you a proper answer. Build-up, quantities, a delivered date, and an honest note on anything we think is the wrong approach.