Manufactured in India, supplied in Pune
Wooden slat acoustic panels in Pune
We manufacture wooden slat acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Pune. Pune builds new townships and runs an automotive belt at the same time, so we supply apartment towers and press shops in the same week.
- Substrate
- MDF, FR MDF, HDF or HDHMR
- Patterns
- 13-3, 14-2, 28-4 and 59-5
- Panel sizes
- 2440 x 192 mm and 2440 x 128 mm
- Thickness
- 14, 16 and 18 mm
- Coverage
- 96 sq ft per unit
- Lead time
- Longer than felt
- Minimum order
- 500 sq ft, about 46 sq m
- EN 13501-1 Class B s1 d0 on FR substrate
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
We are the manufacturer. There is no local office and we do not claim approvals we do not hold. What you get is factory pricing, one consistent batch across the order, and a straight answer on what the material will and will not do.
01 / What it is
The product, described honestly, for a Pune brief
Timber slats on an acoustic backing. The slats are the finish and the rhythm, the backing does the absorbing. Used where the room has to look considered rather than treated.
Work reaching us from Pune is mostly automotive and engineering plants, townships and apartment towers, IT offices, colleges, clinics.
Towers and chawls side by side, in RC frame with tile floors. Redevelopment stock shares slabs and lift cores, and monsoon damp rules out anything that holds moisture.
- Slats on felt backing The standard. Absorption comes from the backing behind the gaps, so the slat gap ratio is an acoustic decision, not only a visual one.
- Slats on a cavity Backing plus an air gap behind moves absorption lower, which matters in music rooms.
- Feature wall only Slats where they are seen, plain felt elsewhere, to hold the budget where it shows.
- What it will not do A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for wooden slat panels are on the main product page. This page covers what that means for a project in Pune.
02 / The numbers
Published specification, identical wherever we ship it
These figures are published and they do not move. The thing worth arguing about is not the number on the sheet, it is which grade and which build-up suits the room you are treating.
- MDFStandard. Dry interiors, general commercial
- FR MDFFire rated. Public buildings and anywhere the specification calls for a class
- HDHMRMoisture resistant. Humid climates and rooms that see damp
| Substrate | MDF, FR MDF, HDF or HDHMR |
|---|---|
| Patterns | 13-3, 14-2, 28-4 and 59-5 |
| Panel sizes | 2440 x 192 mm and 2440 x 128 mm |
| Thickness | 14, 16 and 18 mm |
| Coverage | 96 sq ft per unit |
| Fire class | EN 13501-1 Class B s1 d0 on FR substrate |
If a consultant has set the target, we will quote against their figures rather than ours, and stay out of the scope they own. More on working with acoustic consultants.
03 / On the ground
What decides the build-up in Pune
- Machinery, not conversation
Presses, compressors and test rigs are low frequency and structure-borne. Enclosure at the source is the only thing that addresses them.
- New townships, repeated details
The same separating wall across hundreds of flats. Getting it right on the drawing is far cheaper than fixing it after possession.
- Education and test rooms
Colleges and engineering centres with rooms that need a genuinely low background before measurement means anything.
- Monsoon damp
PET felt does not absorb moisture or feed mould, which matters where mineral products sag within a couple of seasons.
- Assembly and performance rooms
Auditoriums, banquet halls and places of worship are large hard volumes in concrete and stone where speech falls apart long before anyone calls the room echoey.
We would rather argue about the build-up at design stage than on site. See how we support architects.
04 / Conditions
Why the climate in Pune changes the material, not the target
Pune is warm and humid through most of the year, with a long wet season, and that narrows the sensible material list before acoustics is even discussed.
Humidity is the deciding factor. PET felt does not absorb moisture, shed fibre or feed mould, which is why it outlasts fabric-wrapped mineral wool in this climate. Wood wool and timber need a ventilated cavity behind them.
The risk we design against here is mould, sagging fabric finishes and swelling in timber.
If the visual is fixed and the room still has to perform, that is a solvable problem and a conversation worth having early. See how we work with interior designers.
05 / Logistics
Supply into Pune, start to site
| Made at | Our own plant, Palwal, Haryana |
|---|---|
| Reaches site in | three to four days |
| Dispatch | 2 to 4 working days |
| To site | three to four days |
| Packing | Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry. |
| Lead time | Longer than felt. Confirmed against the pattern and substrate at quote stage. |
Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.
By road from Palwal, roughly fourteen hundred kilometres, normally three to four days on a dedicated truck.
500 sq ft, about 46 sq m, whatever the substrate, pattern, width or thickness.
| Any specification | 500 sq ft, about 46 sq m |
|---|
One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order.
06 / Before you buy
Where this goes wrong, said plainly
-
The wrong product for the problem
A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
-
Coverage bought instead of a target
Lining every surface is a purchase, not a result. We would rather calculate the area against a reverberation target and sell you less of it.
-
Local approvals that nobody actually holds
We hold no Pune certification and we will not borrow one. The test data we publish is ours, and we will send the reports rather than describe them.
Pune: questions we are actually asked
Are these wooden slat acoustic panels made in Pune?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Pune as the manufacturer rather than through a dealer. Pune builds new townships and runs an automotive belt at the same time, so we supply apartment towers and press shops in the same week. You buy at factory prices with one consistent batch across the order.
What do you look at first on a Pune enquiry?
Presses, compressors and test rigs are low frequency and structure-borne. Enclosure at the source is the only thing that addresses them. The same separating wall across hundreds of flats. Getting it right on the drawing is far cheaper than fixing it after possession. Those two things move the build-up far more than the panel figure does.
Is this the right material for Pune conditions?
Pune is warm and humid through most of the year, with a long wet season. Humidity is the deciding factor. PET felt does not absorb moisture, shed fibre or feed mould, which is why it outlasts fabric-wrapped mineral wool in this climate. Wood wool and timber need a ventilated cavity behind them. The failure we design against here is mould, sagging fabric finishes and swelling in timber.
When would material land on a Pune site?
made at: Our own plant, Palwal, Haryana, reaches site in: three to four days, dispatch: 2 to 4 working days. Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.
What will wooden slat acoustic panels not do?
A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
Is there a minimum order, and how does it arrive?
500 sq ft, about 46 sq m, whatever the substrate, pattern, width or thickness. Any specification, 500 sq ft, about 46 sq m. One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order. Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.
Next step
Send a plan and a section, get a real build-up
We quote from drawings, not from a square foot rate. Send a plan and the section through the critical wall or ceiling and you will get something you can actually build from.