Manufactured in India, supplied in Mysuru
Wooden slat acoustic panels in Mysuru
We manufacture wooden slat acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Mysuru. Mysuru is heritage tourism and education in a mild climate, which makes it one of the more straightforward southern markets to specify for.
- Substrate
- MDF, FR MDF, HDF or HDHMR
- Patterns
- 13-3, 14-2, 28-4 and 59-5
- Panel sizes
- 2440 x 192 mm and 2440 x 128 mm
- Thickness
- 14, 16 and 18 mm
- Coverage
- 96 sq ft per unit
- Lead time
- Longer than felt
- Minimum order
- 500 sq ft, about 46 sq m
- EN 13501-1 Class B s1 d0 on FR substrate
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
This comes from our own plant, not a trading desk. We do not have an office in your city and we will not invent one. What we can give you is factory pricing, consistent material and a technical answer before you commit.
01 / The product
What this is, and what it changes in a Mysuru room
Timber slats on an acoustic backing. The slats are the finish and the rhythm, the backing does the absorbing. Used where the room has to look considered rather than treated.
Work reaching us from Mysuru is mostly heritage hotels, colleges and schools, auditoriums, hospitals, offices, restaurants.
RC frame apartments and independent houses with tile and stone floors, in dense neighbourhoods where buildings sit a few feet apart.
- Slats on felt backing The standard. Absorption comes from the backing behind the gaps, so the slat gap ratio is an acoustic decision, not only a visual one.
- Slats on a cavity Backing plus an air gap behind moves absorption lower, which matters in music rooms.
- Feature wall only Slats where they are seen, plain felt elsewhere, to hold the budget where it shows.
- What it will not do A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for wooden slat panels are on the main product page. This page covers what that means for a project in Mysuru.
02 / Specification
Published specification, identical wherever we ship it
Nothing below changes by location. The decisions that do change are grade, thickness and how the material is mounted, and those are covered further down.
- MDFStandard. Dry interiors, general commercial
- FR MDFFire rated. Public buildings and anywhere the specification calls for a class
- HDHMRMoisture resistant. Humid climates and rooms that see damp
| Substrate | MDF, FR MDF, HDF or HDHMR |
|---|---|
| Patterns | 13-3, 14-2, 28-4 and 59-5 |
| Panel sizes | 2440 x 192 mm and 2440 x 128 mm |
| Thickness | 14, 16 and 18 mm |
| Coverage | 96 sq ft per unit |
| Fire class | EN 13501-1 Class B s1 d0 on FR substrate |
Where a consultant is already engaged on a Mysuru project, we supply to their specification and send the test reports rather than describing them. More on working with acoustic consultants.
03 / In this market
What the buildings in Mysuru do to the specification
- Heritage fabric stays
Stone and lime plaster in tall rooms that cannot be altered. Work has to be internal, shallow and ideally reversible.
- Education at scale
A large college sector with lecture rooms and halls where speech fails long before the room is called echoey.
- A mild climate
Less aggressive on materials than the coast, which widens the sensible options rather than narrowing them.
- Four to five days by road
A long run, confirmed before dispatch, with samples sent ahead of the order.
- Assembly and performance rooms
Auditoriums, banquet halls and places of worship are large hard volumes in concrete and stone where speech falls apart long before anyone calls the room echoey.
We would rather argue about the build-up at design stage than on site. See how we support architects.
04 / Climate and durability
What the Mysuru climate rules in and rules out
Mysuru is warm and humid through most of the year, with a long wet season, and that narrows the sensible material list before acoustics is even discussed.
Humidity is the deciding factor. PET felt does not absorb moisture, shed fibre or feed mould, which is why it outlasts fabric-wrapped mineral wool in this climate. Wood wool and timber need a ventilated cavity behind them.
The risk we design against here is mould, sagging fabric finishes and swelling in timber.
Interior designers tend to arrive with the look already decided. We will tell you which finish gets there without losing the acoustics. See how we work with interior designers.
05 / Supply
Getting it to Mysuru, with real dates
| Made at | Our own plant, Palwal, Haryana |
|---|---|
| Reaches site in | four to five days |
| Dispatch | 2 to 4 working days |
| To site | four to five days |
| Packing | Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry. |
| Lead time | Longer than felt. Confirmed against the pattern and substrate at quote stage. |
Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.
By road from Palwal, roughly twenty two hundred kilometres, normally four to five days on a dedicated truck.
500 sq ft, about 46 sq m, whatever the substrate, pattern, width or thickness.
| Any specification | 500 sq ft, about 46 sq m |
|---|
One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order.
06 / Straight talk
The things worth knowing before you place the order
-
The wrong product for the problem
A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
-
A number chased without a measurement
If nobody has measured the room or set a target, the specification is a guess with a decimal point in it. We will ask for the target before we quote the quantity.
-
Suppliers who imply a Mysuru presence
Ask any supplier where the material is made and who carries the warranty. We make it at Palwal in Haryana and we say so on every page, including this one.
Mysuru: questions we are actually asked
Where are the wooden slat acoustic panels you supply to Mysuru actually made?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Mysuru as the manufacturer rather than through a dealer. Mysuru is heritage tourism and education in a mild climate, which makes it one of the more straightforward southern markets to specify for. You buy at factory prices with one consistent batch across the order.
What decides the specification for a Mysuru project?
Stone and lime plaster in tall rooms that cannot be altered. Work has to be internal, shallow and ideally reversible. A large college sector with lecture rooms and halls where speech fails long before the room is called echoey. Those two things move the build-up far more than the panel figure does.
Does Mysuru weather shorten the life of this material?
Mysuru is warm and humid through most of the year, with a long wet season. Humidity is the deciding factor. PET felt does not absorb moisture, shed fibre or feed mould, which is why it outlasts fabric-wrapped mineral wool in this climate. Wood wool and timber need a ventilated cavity behind them. The failure we design against here is mould, sagging fabric finishes and swelling in timber.
When would material land on a Mysuru site?
made at: Our own plant, Palwal, Haryana, reaches site in: four to five days, dispatch: 2 to 4 working days. Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.
Where do wooden slat acoustic panels fail to help?
A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.
What is the minimum order and how is it packed?
500 sq ft, about 46 sq m, whatever the substrate, pattern, width or thickness. Any specification, 500 sq ft, about 46 sq m. One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order. Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.
Next step
Drawings in, BOQ and a delivered date out
One drawing gets you a proper answer. Build-up, quantities, a delivered date, and an honest note on anything we think is the wrong approach.