Home > Hosur > Wooden slat acoustic panels

Acoustic wooden slat wall and ceiling in a premium auditorium

Manufactured in India, supplied in Hosur

Wooden slat acoustic panels in Hosur

We manufacture wooden slat acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Hosur. Hosur is a manufacturing town on the edge of Bengaluru, and most of what we supply goes into new plants and the offices attached to them.

Substrate
MDF, FR MDF, HDF or HDHMR
Patterns
13-3, 14-2, 28-4 and 59-5
Panel sizes
2440 x 192 mm and 2440 x 128 mm
Thickness
14, 16 and 18 mm
Coverage
96 sq ft per unit
Lead time
Longer than felt
Minimum order
500 sq ft, about 46 sq m
  • EN 13501-1 Class B s1 d0 on FR substrate
  • Made at our own plant, Palwal, Haryana, India
  • One batch across the order, no blending between runs

Manufacturer, not reseller. We hold no local approvals and will not imply we do. You get the price the factory quotes, material that matches across a large order, and advice that sometimes talks you out of a purchase.

01 / The product

What this material is and where it earns its place in Hosur

Timber slats on an acoustic backing. The slats are the finish and the rhythm, the backing does the absorbing. Used where the room has to look considered rather than treated.

Work reaching us from Hosur is mostly electronics and automotive plants, test and QC rooms, offices, canteens, training rooms, hostels.

RC frame houses and apartments with hard floors, built for heat and humidity with open plan layouts that carry sound room to room.

  • Slats on felt backing The standard. Absorption comes from the backing behind the gaps, so the slat gap ratio is an acoustic decision, not only a visual one.
  • Slats on a cavity Backing plus an air gap behind moves absorption lower, which matters in music rooms.
  • Feature wall only Slats where they are seen, plain felt elsewhere, to hold the budget where it shows.
  • What it will not do A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

Full specification

Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for wooden slat panels are on the main product page. This page covers what that means for a project in Hosur.

Wooden slat acoustic panels SoundaXe wooden panels

02 / Data sheet

One specification sheet, the same in every market

Nothing below changes by location. The decisions that do change are grade, thickness and how the material is mounted, and those are covered further down.

  • MDFStandard. Dry interiors, general commercial
  • FR MDFFire rated. Public buildings and anywhere the specification calls for a class
  • HDHMRMoisture resistant. Humid climates and rooms that see damp
Wooden slat acoustic panels: published specification
SubstrateMDF, FR MDF, HDF or HDHMR
Patterns13-3, 14-2, 28-4 and 59-5
Panel sizes2440 x 192 mm and 2440 x 128 mm
Thickness14, 16 and 18 mm
Coverage96 sq ft per unit
Fire classEN 13501-1 Class B s1 d0 on FR substrate

If a consultant has set the target, we will quote against their figures rather than ours, and stay out of the scope they own. More on working with acoustic consultants.

03 / In this market

What we see driving Hosur briefs

  • New plants, decisions still open

    On a greenfield build the enclosure and the partition can be designed in, which costs a fraction of fixing it after commissioning.

  • Test and clean areas

    QC and measurement rooms need a low background before any result means anything. That is isolation with a written target.

  • Canteens and training rooms

    Large hard rooms where hundreds of people eat or listen. Ceiling absorption does almost all of the work.

  • Four to five days by road

    A dedicated truck from Palwal, with samples sent ahead so the finish is approved before the order.

  • Assembly and performance rooms

    Kalyana mandapams, temple halls and auditoria are very large hard volumes carrying amplified speech and music.

We would rather argue about the build-up at design stage than on site. See how we support architects.

04 / Conditions

Durability in Hosur, before acoustics is discussed

Hosur is warm and humid through most of the year, with a long wet season, and that narrows the sensible material list before acoustics is even discussed.

Humidity is the deciding factor. PET felt does not absorb moisture, shed fibre or feed mould, which is why it outlasts fabric-wrapped mineral wool in this climate. Wood wool and timber need a ventilated cavity behind them.

The risk we design against here is mould, sagging fabric finishes and swelling in timber.

If the visual is fixed and the room still has to perform, that is a solvable problem and a conversation worth having early. See how we work with interior designers.

05 / Logistics

Getting it to Hosur, with real dates

Supply into Hosur
Made atOur own plant, Palwal, Haryana
Reaches site infour to five days
Dispatch2 to 4 working days
To sitefour to five days
PackingBraced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.
Lead timeLonger than felt. Confirmed against the pattern and substrate at quote stage.

Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.

By road from Palwal, roughly two thousand two hundred kilometres, normally four to five days on a dedicated truck.

500 sq ft, about 46 sq m, whatever the substrate, pattern, width or thickness.

Minimum order, wooden slat acoustic panels
Any specification500 sq ft, about 46 sq m

One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order.

06 / Straight talk

Four honest warnings before you buy

  • The wrong product for the problem

    A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

  • Coverage bought instead of a target

    Lining every surface is a purchase, not a result. We would rather calculate the area against a reverberation target and sell you less of it.

  • A claim of being local to Hosur

    We manufacture in India and supply here. We do not run an office in this city and we will not pretend to, because you would find out on the first site visit.

FAQ

Hosur: questions we are actually asked

Where are the wooden slat acoustic panels you supply to Hosur actually made?

No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Hosur as the manufacturer rather than through a dealer. Hosur is a manufacturing town on the edge of Bengaluru, and most of what we supply goes into new plants and the offices attached to them. You buy at factory prices with one consistent batch across the order.

What do you look at first on a Hosur enquiry?

On a greenfield build the enclosure and the partition can be designed in, which costs a fraction of fixing it after commissioning. QC and measurement rooms need a low background before any result means anything. That is isolation with a written target. Those two things move the build-up far more than the panel figure does.

How does the Hosur climate affect this product?

Hosur is warm and humid through most of the year, with a long wet season. Humidity is the deciding factor. PET felt does not absorb moisture, shed fibre or feed mould, which is why it outlasts fabric-wrapped mineral wool in this climate. Wood wool and timber need a ventilated cavity behind them. The failure we design against here is mould, sagging fabric finishes and swelling in timber.

How does an order actually travel to Hosur?

made at: Our own plant, Palwal, Haryana, reaches site in: four to five days, dispatch: 2 to 4 working days. Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.

Where do wooden slat acoustic panels fail to help?

A tight slat pattern looks denser but absorbs less, because the open area is what lets sound reach the backing. If the visual you want and the RT target you need pull apart, we will tell you which one the pattern is serving.

What quantity do we have to order, and in what packaging?

500 sq ft, about 46 sq m, whatever the substrate, pattern, width or thickness. Any specification, 500 sq ft, about 46 sq m. One unit covers 96 sq ft, so the minimum is a little over five units. Substrate, slat pattern, width and thickness can be mixed inside the same order. Braced crates, slats supported along their length. Timber moves, so crates are kept flat and dry.

Next step

Send a plan and a section, get a real build-up

A plan and a section is enough. We will come back with a build-up, a BOQ and a delivered date, and we will say so if what you are asking for will not work.