Manufactured in India, supplied in Colombia
Wood wool acoustic panels in Colombia
We manufacture wood wool acoustic panels at our own plant at Palwal in Haryana, India, and supply them into Colombia. Made at our own plant in India and shipped into Cartagena or Buenaventura, then road inland, with the inland climb quoted separately.
- Panel size
- 1200 x 600 mm
- Thickness
- 20 mm
- Density
- 400 kg per cubic metre
- NRC
- 0.30
- Test standards
- ASTM C-423 and EN ISO 354
- Lead time
- 4 to 7 working days for standard sizes
- Minimum order
- 500 sq ft, about 46 sq m
- ASTM C-423 and EN ISO 354
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
Manufacturer, not reseller. We hold no local approvals and will not imply we do. You get the price the factory quotes, material that matches across a large order, and advice that sometimes talks you out of a purchase.
01 / The material
What this is, and what it changes in a Colombia room
Wood fibre bound into a rigid board with an open texture. Robust, paintable and used where the surface takes knocks, which is why it ends up in schools, sports halls and plant rooms.
Work reaching us from Colombia is mostly offices, apartments, hotels, restaurants, hospitals, schools, studios.
Concrete and block construction with hard floors, in apartment towers that share slabs and walls.
- Direct fix Mechanically fixed to the soffit or wall. Durable and simple.
- On a cavity Mounted on battens with an air gap, which is where the low mid performance comes from.
- With a porous backing Board over mineral backing where the room needs more than the board alone gives.
- What it will not do At 20 mm it is a mid and high frequency absorber, not a bass solution, and painting it heavily will close the surface and reduce what it does. If a room needs low frequency control, depth or a cavity has to come from somewhere.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for wood wool panels are on the main product page. This page covers what that means for a project in Colombia.
02 / Specification
The published figures, unchanged by location
Nothing below changes by location. The decisions that do change are grade, thickness and how the material is mounted, and those are covered further down.
- Natural20 mm. Plant rooms, back of house, industrial
- Painted20 mm. Classrooms, halls, visible ceilings
| Panel size | 1200 x 600 mm |
|---|---|
| Thickness | 20 mm |
| Density | 400 kg per cubic metre |
| NRC | 0.30 |
| Test standards | ASTM C-423 and EN ISO 354 |
| Surface burning | Class A to ASTM E84 |
Where a consultant is already engaged on a Colombia project, we supply to their specification and send the test reports rather than describing them. More on working with acoustic consultants.
03 / On the ground
What we see driving Colombia briefs
- The inland leg is significant
The commercial centres are well inland and high up. We quote the port leg and the road leg separately so the programme runs on real dates.
- Concrete and brick construction
Walls carry mass. The recurring problem is hard, live interiors and services noise rather than speech through a wall.
- Growing hospitality sector
Hotel and restaurant fit-out is a steady share of enquiries, and those rooms are judged when they are completely full.
- Two coasts to choose from
Cartagena on the Caribbean or Buenaventura on the Pacific, routed to whichever shortens the run to your site.
- Assembly and performance rooms
Church buildings, event halls and auditoria are hard volumes carrying amplified music at high level.
- School and campus buildings
Classrooms are concrete and tile with high ceilings, and covered play areas amplify break time noise.
For a Colombia practice, the useful thing is a detail you can put in a drawing set, not a brochure. See how we support architects.
04 / Climate
The Colombia climate decides the material list
Colombia is warm and humid through most of the year, with a long wet season, and that narrows the sensible material list before acoustics is even discussed.
Humidity is the deciding factor. PET felt does not absorb moisture, shed fibre or feed mould, which is why it outlasts fabric-wrapped mineral wool in this climate. Wood wool and timber need a ventilated cavity behind them.
The risk we design against here is mould, sagging fabric finishes and swelling in timber.
Interior designers tend to arrive with the look already decided. We will tell you which finish gets there without losing the acoustics. See how we work with interior designers.
05 / Supply
How material reaches a Colombia site
| Ships from | Palwal, Haryana, India |
|---|---|
| Arrives at | Cartagena or Buenaventura, then road inland |
| Dispatch | 4 to 7 working days |
| Freight | Sea via Cartagena |
| Packing | Palletised flat, edge protected. Boards are rigid but the edges chip, so they travel protected. |
| Lead time | 4 to 7 working days for standard sizes. |
Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.
Sea freight into Cartagena or Buenaventura, then road inland. Air freight for samples and urgent quantities.
The same 500 sq ft minimum applies on export.
| Any finish | 500 sq ft, about 46 sq m |
|---|
A panel is 1200 x 600 mm, which is 0.72 sq m or about 7.75 sq ft, so the minimum is roughly 65 panels.
06 / Before you buy
Where this goes wrong, said plainly
-
The wrong product for the problem
At 20 mm it is a mid and high frequency absorber, not a bass solution, and painting it heavily will close the surface and reduce what it does. If a room needs low frequency control, depth or a cavity has to come from somewhere.
-
A number chased without a measurement
If nobody has measured the room or set a target, the specification is a guess with a decimal point in it. We will ask for the target before we quote the quantity.
-
Suppliers who imply a Colombia presence
Ask any supplier where the material is made and who carries the warranty. We make it at Palwal in Haryana and we say so on every page, including this one.
Colombia: questions we are actually asked
Are these wood wool acoustic panels made in Colombia?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Colombia as the manufacturer rather than through a dealer. Made at our own plant in India and shipped into Cartagena or Buenaventura, then road inland, with the inland climb quoted separately. You buy at factory prices with one consistent batch across the order.
Why would a Colombia build-up differ from anywhere else?
The commercial centres are well inland and high up. We quote the port leg and the road leg separately so the programme runs on real dates. Walls carry mass. The recurring problem is hard, live interiors and services noise rather than speech through a wall. Those two things move the build-up far more than the panel figure does.
Will this material last in the Colombia climate?
Colombia is warm and humid through most of the year, with a long wet season. Humidity is the deciding factor. PET felt does not absorb moisture, shed fibre or feed mould, which is why it outlasts fabric-wrapped mineral wool in this climate. Wood wool and timber need a ventilated cavity behind them. The failure we design against here is mould, sagging fabric finishes and swelling in timber.
How does an order actually travel to Colombia?
ships from: Palwal, Haryana, India, arrives at: Cartagena or Buenaventura, then road inland, dispatch: 4 to 7 working days. Standard items dispatch in 4 to 7 working days. The sea leg from India is long, so plan the full door to door window into the programme. We give real dates, not optimistic ones.
When are wood wool acoustic panels the wrong purchase?
At 20 mm it is a mid and high frequency absorber, not a bass solution, and painting it heavily will close the surface and reduce what it does. If a room needs low frequency control, depth or a cavity has to come from somewhere.
How is the order packed and what is the minimum?
The same 500 sq ft minimum applies on export. Any finish, 500 sq ft, about 46 sq m. A panel is 1200 x 600 mm, which is 0.72 sq m or about 7.75 sq ft, so the minimum is roughly 65 panels. Palletised flat, edge protected. Boards are rigid but the edges chip, so they travel protected.
Next step
Drawings in, BOQ and a delivered date out
One drawing gets you a proper answer. Build-up, quantities, a delivered date, and an honest note on anything we think is the wrong approach.