Home > Aurangabad > Ceiling baffles and clouds
Manufactured in India, supplied in Aurangabad
Ceiling baffles and clouds in Aurangabad
We manufacture ceiling baffles and clouds at our own plant at Palwal in Haryana, India, and supply them into Aurangabad. Aurangabad is an automotive component belt beside a major heritage tourism circuit, so plant rooms and hotels arrive together.
- Material
- 100% PET non-woven, the panel family
- Thickness
- 9 to 24 mm
- Size
- Made to the drawing, standard and custom
- Exposure
- Both faces work, which is why suspended area outperforms the same area laid flat
- Test standard
- ASTM C423
- Lead time
- Confirmed against the drawing
- Minimum order
- 500 sq ft, about 46 sq m
- ASTM C423
- Made at our own plant, Palwal, Haryana, India
- One batch across the order, no blending between runs
We are the manufacturer. There is no local office and we do not claim approvals we do not hold. What you get is factory pricing, one consistent batch across the order, and a straight answer on what the material will and will not do.
01 / Start here
The product, described honestly, for a Aurangabad brief
PET felt suspended from the soffit, vertically as baffles or horizontally as clouds. It is how you treat a room with exposed services, where there is no ceiling to line.
Work reaching us from Aurangabad is mostly automotive component plants, hotels, colleges, hospitals, offices, auditoriums.
Towers and chawls side by side, in RC frame with tile floors. Redevelopment stock shares slabs and lift cores, and monsoon damp rules out anything that holds moisture.
- Vertical baffles Hung on edge in rows. Both faces absorb, so coverage figures based on plan area understate them.
- Horizontal clouds Flat rafts over the occupied zone, which also reflect early speech energy back down where it helps.
- Mixed with services Set out around ducts, trays and lighting rather than fighting them, coordinated from your reflected ceiling plan.
- What it will not do Baffles are efficient, not magic. In a very tall volume the height above the baffle line still rings, and the honest answer is either more area or accepting a higher RT, not a denser panel.
Full specification
Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for baffles and clouds are on the main product page. This page covers what that means for a project in Aurangabad.
Acoustic ceiling baffles Acoustic ceiling clouds Acoustic ceiling tiles
02 / Specification sheet
One specification sheet, the same in every market
Nothing below changes by location. The decisions that do change are grade, thickness and how the material is mounted, and those are covered further down.
- EchoCore 151500 GSM. Offices, retail, general
- EchoPro 181800 GSM. Halls, atria, spaces with a target
- EchoMax 222200 GSM. High volume and high occupancy
| Material | 100% PET non-woven, the panel family |
|---|---|
| Thickness | 9 to 24 mm |
| Size | Made to the drawing, standard and custom |
| Exposure | Both faces work, which is why suspended area outperforms the same area laid flat |
| Test standard | ASTM C423 |
Where a consultant is already engaged on a Aurangabad project, we supply to their specification and send the test reports rather than describing them. More on working with acoustic consultants.
03 / In this market
What we see driving Aurangabad briefs
- Presses and conveyors
Continuous machinery running all shift. Enclosure and barrier at the source, not absorption on a far wall.
- Test and QC rooms
Measurement spaces that need a genuinely low background before any reading means anything.
- Seasonal hotel occupancy
Rooms full in season and empty out of it, so the design has to work at capacity.
- Three days by road
A dedicated truck from Palwal, with samples sent ahead so the finish is approved first.
- School and campus buildings
Schools range from compact municipal buildings to large private campuses, all hard surfaced, with assembly halls doing duty as performance spaces.
Architects working in Aurangabad usually need the build-up before the product. We will draw the section and mark what does the work. See how we support architects.
04 / Durability
Why the climate in Aurangabad changes the material, not the target
Aurangabad is warm and humid through most of the year, with a long wet season, and that narrows the sensible material list before acoustics is even discussed.
Humidity is the deciding factor. PET felt does not absorb moisture, shed fibre or feed mould, which is why it outlasts fabric-wrapped mineral wool in this climate. Wood wool and timber need a ventilated cavity behind them.
The risk we design against here is mould, sagging fabric finishes and swelling in timber.
Interior designers tend to arrive with the look already decided. We will tell you which finish gets there without losing the acoustics. See how we work with interior designers.
05 / Getting it there
What the route into Aurangabad actually looks like
| Made at | Our own plant, Palwal, Haryana |
|---|---|
| Reaches site in | three days |
| Dispatch | 2 to 4 working days |
| To site | three days |
| Packing | Flat packed with fixings, sets labelled by row so the install sequence matches the drawing. |
| Lead time | Confirmed against the drawing. Standard sizes 4 to 7 working days. |
Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.
By road from Palwal, roughly twelve hundred kilometres, normally three days on a dedicated truck.
500 sq ft, about 46 sq m, across baffles and clouds together.
| Baffles and clouds | 500 sq ft, about 46 sq m |
|---|
Baffles and clouds are cut to the drawing, so the minimum is counted on finished panel area. Both faces of a hung baffle absorb, which is why coverage taken off a plan understates what the order actually does.
06 / Before you buy
What we will tell you that a reseller will not
-
The wrong product for the problem
Baffles are efficient, not magic. In a very tall volume the height above the baffle line still rings, and the honest answer is either more area or accepting a higher RT, not a denser panel.
-
Square footage quoted before the room is understood
Anyone can price a wall. Working out how much material the room actually needs usually reduces the order, which is why not everyone does it.
-
Local approvals that nobody actually holds
We hold no Aurangabad certification and we will not borrow one. The test data we publish is ours, and we will send the reports rather than describe them.
Aurangabad: questions we are actually asked
Where are the ceiling baffles and clouds you supply to Aurangabad actually made?
No, and we will not say otherwise. We manufacture at our own plant at Palwal in Haryana, India, and supply into Aurangabad as the manufacturer rather than through a dealer. Aurangabad is an automotive component belt beside a major heritage tourism circuit, so plant rooms and hotels arrive together. You buy at factory prices with one consistent batch across the order.
Why would a Aurangabad build-up differ from anywhere else?
Continuous machinery running all shift. Enclosure and barrier at the source, not absorption on a far wall. Measurement spaces that need a genuinely low background before any reading means anything. Those two things move the build-up far more than the panel figure does.
Is this the right material for Aurangabad conditions?
Aurangabad is warm and humid through most of the year, with a long wet season. Humidity is the deciding factor. PET felt does not absorb moisture, shed fibre or feed mould, which is why it outlasts fabric-wrapped mineral wool in this climate. Wood wool and timber need a ventilated cavity behind them. The failure we design against here is mould, sagging fabric finishes and swelling in timber.
When would material land on a Aurangabad site?
made at: Our own plant, Palwal, Haryana, reaches site in: three days, dispatch: 2 to 4 working days. Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.
Where do ceiling baffles and clouds fail to help?
Baffles are efficient, not magic. In a very tall volume the height above the baffle line still rings, and the honest answer is either more area or accepting a higher RT, not a denser panel.
What is the minimum order and how is it packed?
500 sq ft, about 46 sq m, across baffles and clouds together. Baffles and clouds, 500 sq ft, about 46 sq m. Baffles and clouds are cut to the drawing, so the minimum is counted on finished panel area. Both faces of a hung baffle absorb, which is why coverage taken off a plan understates what the order actually does. Flat packed with fixings, sets labelled by row so the install sequence matches the drawing.
Next step
Send a plan and a section, get a real build-up