Home > Thane > HVAC, plant and machine noise control

HVAC duct and condenser noise control in Abu Dhabi

For projects in Thane

HVAC, plant and machine noise control in Thane

Noise with a source. Almost every honest fix is at the machine, the duct or the plant room, and almost nothing useful happens by lining the far wall of the occupied space. Split units, VRF outdoor banks and diesel generator sets sit close to occupied areas, often on the same terrace as a bedroom. Generator enclosure and condenser screening are the recurring jobs.

At source
Enclosure, barrier or anti vibration mounts at the machine.
In the path
Duct lining, attenuators and lagging on the first run out of the plant.
At the receiver
Only after the first two, and only for what is left.
Quote
From a plan and a section, within 48 hours

01 / What it is

The material, and what it actually does on a Thane job

Noise with a source. Almost every honest fix is at the machine, the duct or the plant room, and almost nothing useful happens by lining the far wall of the occupied space.

Split units, VRF outdoor banks and diesel generator sets sit close to occupied areas, often on the same terrace as a bedroom. Generator enclosure and condenser screening are the recurring jobs.

Work reaching us from Thane is mostly residential towers and redevelopment, offices, malls and retail, restaurants, schools, clinics.

  • Impact noise from above Footfall through a slab is the most common complaint we get from this city. It is a floor problem, and treating the ceiling below rarely fixes it.
  • Redevelopment at speed Old buildings replaced by towers, built fast to a fixed cost. Acoustic detail is easy to lose unless it is specified early.
  • Lifts, pumps and services Shafts and pump rooms sit next to bedrooms in tight plans. That is an isolation job at the source.
  • At source Enclosure, barrier or anti vibration mounts at the machine.

Full specification

Thickness, density, NRC by frequency, fire class, standard sizes and build-up detail for HVAC and plant noise control are on the main product page. This page covers what that means for a project in Thane.

HVAC duct soundproofing Machine noise control

02 / The build-up

How the layers stack, from the structure inwards

  1. Soundproofing Material & Noise Isolation Supplier in Abu Dhabi

    Layer 1

    Soundproofing materials

    The blocking side of the range taken together: mass loaded vinyl, resilient layers, cavity absorption and the build-ups they belong in. In Thane, split units, VRF outdoor banks and diesel generator sets sit close to occupied areas, often on the same terrace as a bedroom. Generator enclosure and condenser screening are the recurring jobs.

    Independent leaf. A second wall that does not touch the first. Nothing else comes close for the money.

  2. Acoustic Foam Panels & Echo Control in Abu Dhabi

    Layer 2

    Acoustic foam and BassBloc

    Open cell foam shapes for high frequency control, and BassBloc, a high density absorber built for the low mid range where ordinary foam does nothing. In Thane, auditoriums, banquet halls and places of worship are large hard volumes in concrete and stone where speech falls apart long before anyone calls the room echoey.

    Corner loading. Low frequency energy collects in corners, so absorber in the corners does more than the same area spread across a wall.

  3. Acoustic hanging ceiling baffles in a large open space

    Layer 3

    Ceiling baffles and clouds

    PET felt suspended from the soffit, vertically as baffles or horizontally as clouds. In Thane, schools range from compact municipal buildings to large private campuses, all hard surfaced, with assembly halls doing duty as performance spaces.

    Vertical baffles. Hung on edge in rows. Both faces absorb, so coverage figures based on plan area understate them.

If you are specifying for a Thane project, we can give you a section, a BOQ and the honest limits of each layer. See how we support architects.

03 / On the ground

The Thane conditions that change the answer

  • Impact noise from above

    Footfall through a slab is the most common complaint we get from this city. It is a floor problem, and treating the ceiling below rarely fixes it.

  • Redevelopment at speed

    Old buildings replaced by towers, built fast to a fixed cost. Acoustic detail is easy to lose unless it is specified early.

  • Lifts, pumps and services

    Shafts and pump rooms sit next to bedrooms in tight plans. That is an isolation job at the source.

  • Coastal humidity

    PET felt does not absorb moisture or feed mould, which matters where monsoon damp defeats mineral products.

  • Plant and HVAC

    Split units, VRF outdoor banks and diesel generator sets sit close to occupied areas, often on the same terrace as a bedroom. Generator enclosure and condenser screening are the recurring jobs.

04 / Room by room

What each space in a Thane project needs

If the visual is fixed and the room still has to perform, that is a solvable problem and a conversation worth having early. See how we work with interior designers.

04 / Conditions

Durability in Thane, before acoustics is discussed

Thane is warm and humid through most of the year, with a long wet season, and that narrows the material list before acoustics is discussed.

Humidity is the deciding factor. PET felt does not absorb moisture, shed fibre or feed mould, which is why it outlasts fabric-wrapped mineral wool in this climate. Wood wool and timber need a ventilated cavity behind them.

The failure we design against here is mould, sagging fabric finishes and swelling in timber.

Where a consultant is already engaged on a Thane project, we supply to their specification and send the test reports rather than describing them. More on working with acoustic consultants.

06 / Straight talk

Where this kind of project usually fails

  • Absorption on the office wall for a plant room problem

    Enclose the machine, break the vibration path, then deal with what is left. Doing it in the other order costs more and achieves less.

  • Lagging a duct that is carrying the noise as breakout from the fan

    Plant noise treated as a room problem is the most reliable way to spend a budget and change nothing anyone can hear.

  • Ignoring structure borne vibration through the mounts

    This is the one that comes back as a second fit-out rather than a snag.

  • Treating it as a generic Thane job

    Footfall through a slab is the most common complaint we get from this city. It is a floor problem, and treating the ceiling below rarely fixes it.

05 / Supply

What the route into Thane actually looks like

Supply into Thane
Made atOur own plant, Palwal, Haryana
Reaches site inthree to four days
Dispatch2 to 4 working days
To sitethree to four days
SupportDrawings, build-ups, BOQ and material that arrives complete

Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.

By road from Palwal, roughly fourteen hundred kilometres, normally three to four days on a dedicated truck.

FAQ

Questions from Thane projects

What makes HVAC, plant and machine noise control different in Thane?

Split units, VRF outdoor banks and diesel generator sets sit close to occupied areas, often on the same terrace as a bedroom. Generator enclosure and condenser screening are the recurring jobs. Footfall through a slab is the most common complaint we get from this city. It is a floor problem, and treating the ceiling below rarely fixes it.

Where should the budget go first on a Thane project?

At source. Enclosure, barrier or anti vibration mounts at the machine. In the path. Duct lining, attenuators and lagging on the first run out of the plant.

Do you have an office or installation team in Thane?

No. We manufacture in India and supply into Thane. We give you drawings, build-ups, a BOQ and material that arrives complete, and we will tell you plainly when a job needs a local contractor we cannot be.

How does material get to a Thane site?

made at: Our own plant, Palwal, Haryana, reaches site in: three to four days, dispatch: 2 to 4 working days. Standard items dispatch in 2 to 4 working days from our plant at Palwal. Grooved panels and custom colours take longer, and we say so before you order, not after.

What goes wrong most often on this kind of project?

Absorption on the office wall for a plant room problem. Lagging a duct that is carrying the noise as breakout from the fan.

What do you need from us to quote?

A plan, a section through the critical partition or ceiling, and what the room is for. From that we can give a build-up and a BOQ rather than a price per square foot.

Next step

Drawings in, BOQ and a delivered date out

We quote from drawings, not from a square foot rate. Send a plan and the section through the critical wall or ceiling and you will get something you can actually build from.